During normal operation the OK LED lights steadily.
The following LEDs indicate a problem:
The red FAIL LED above the FPC on the craft interface
is lit.
The OK for the FPC on the craft interface
is off.
Solution
If the red FAIL LED above the FPC is on, look
at the display on the craft interface to check the status of the FPC
and the PICs that are plugged into it.
Make sure the FPC is properly seated in the midplane.
Verify that each ejector handle has been turned clockwise and is tight.
Use a screwdriver to verify that the screws inside the ejector handles
are tight.
To check the status of an FPC, use the following CLI command:
user@host> show chassis fpc
To display more detailed information, use the following option: