Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Download Software
Research a Problem Login required
Case Management Login required
Contract & Product Management Login required
Technical Documentation
Documentation Archive
Enterprise MIBs
File Format Help
Glossary
Portable Libraries
End-of-Life Products
Contact Support
Guidelines and Policies
Security Resources
Home > Support > Technical Documentation > MX Series Routers > MX960 Router Hardware > Troubleshooting the MX960 DPCs
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • MX Series
  • MX960 Dense Port Concentrator Description
  • Installing an MX960 DPC
  • Maintaining MX960 DPCs
 

Troubleshooting the MX960 DPCs

Problem

The DPCs are not functioning normally.

Solution

  • Monitor the green LED labeled OK above the DPC on the craft interface as soon as a DPC is seated in an operating router.

    The Routing Engine downloads the DPC software to it under two conditions: the DPC is present when the Routing Engine boots Junos OS, and the DPC is installed and requested online through the CLI or push button on the front panel. The DPC then runs diagnostics, during which the OK LED blinks. When the DPC is online and functioning normally, the OK LED lights green steadily.

  • Make sure the DPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight.
  • Check the OK/FAIL LED on the DPC and OK and FAIL DPC LEDs on the craft interface. When the DPC is online and functioning normally, the OK LED lights green steadily.
  • Issue the show chassis fpc command to check the status of installed DPCs. As shown in the sample output, the value Online in the column labeled State indicates that the DPC is functioning normally:
    user@host> show chassis fpc
                  Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online            41      9          0       1024       15         57
      1  Online            43      5          0       1024       16         57
      2  Online            43     11          0       1024       16         57
      3  Empty
      4  Empty
      5  Online            42      6          0       1024       16         57
     

    Note: The show chassis fpc command displays the status of the DPCs.

    For more detailed output, add the detail option. The following example does not specify a slot number, which is optional:

    user@host> show chassis fpc detail
    Slot 2 information:
      State                               Online
      Temperature                      22 degrees C / 71 degrees F
      Total CPU DRAM                 1024 MB
      Total SRAM                      256 MB
      Total SDRAM                       0 MB
      Start time                          2006-11-03 07:35:40 PST
      Uptime                              2 hours, 27 minutes, 1 second
    Slot 4 information:
      State                               Online
      Temperature                      22 degrees C / 71 degrees F
      Total CPU DRAM                 1024 MB
      Total SRAM                      256 MB
      Total SDRAM                       0 MB
      Start time                          2006-11-03 07:35:48 PST
      Uptime                              2 hours, 26 minutes, 53 seconds
    Slot 7 information:
      State                               Online
      Temperature                      24 degrees C / 75 degrees F
      Total CPU DRAM                 1024 MB
      Total SRAM                      256 MB
      Total SDRAM                       0 MB
      Start time                          2006-11-03 07:35:53 PST
      Uptime                              2 hours, 26 minutes, 48 seconds
    

    For further description of the output from the commands, see the Junos OS System Basics Configuration Guide PDF Document.

 

Related Documentation

  • MX Series
  • MX960 Dense Port Concentrator Description
  • Installing an MX960 DPC
  • Maintaining MX960 DPCs
 

Published: 2011-09-08

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out