Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Support
Technical Documentation
Content Explorer New
 
Enterprise MIBs
 
EOL Documentation
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > T Series Routers > TX Matrix Plus Router Hardware > Taking a Switching Data Plane Offline
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • T Series
  • Replacing a TXP-F13 SIB
  • Replacing a TXP-F2S SIB
  • Replacing a Fiber-Optic Array Cable
  • Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool
 

Taking a Switching Data Plane Offline

Before you replace a TXP-F13 SIB, TXP-F2s SIB, fiber-optic array cable, clean fiber-optic array cables, you can take the data switching plane offline to avoid performance degredation.

  1. Issue the show chassis fabric plane-location command to identify the switching plane affected by the replacement or maintenance procedure. For example, the TXP-F13 SIB in slot 6 resides in switching plane 2. The corresponding TXP-F2 SIBs are 2/0, 2/2, 2/4, 2/6.
    user@host> show chassis fabric plane-location
    Fabric Plane Locations :
    Plane       SFC SIB-F13        SFC SIB-F2        LCC ST-SIB-L
     0             0, 1              0/0, 0/2, 0/4, 0/6           0
     1             3, 4              1/0, 1/2, 1/4, 1/6           1
     2             6, 7              2/0, 2/2, 2/4, 2/6           2
     3             8, 9              3/0, 3/2, 3/4, 3/6           3
     4             11, 12            4/0, 4/2, 4/4, 4/6           4
  2. Determine if the component resides in an active switching plane and verify that there is a spare plane by issuing the show chassis fabric plane detail command:
    user@host> show chassis fabric plane detail
    sfc0-re0:
    --------------------------------------------------------------------------
    Fabric Management PLANE State:
    PLANE  0:    Online           
       SIB F13 0   :    Online          
       SIB F13 1   :    Online          
       SIB F2S 0/0 :    Online          
       SIB F2S 0/2 :    Online          
       SIB F2S 0/4 :    Online          
       SIB F2S 0/6 :    Online          
    PLANE  1:    Online           
       SIB F13 3   :    Online          
       SIB F13 4   :    Online          
       SIB F2S 1/0 :    Online          
       SIB F2S 1/2 :    Online          
       SIB F2S 1/4 :    Online          
       SIB F2S 1/6 :    Online          
    PLANE  2:    Online           
       SIB F13 6   :    Online           
       SIB F13 7   :    Online          
       SIB F2S 2/0 :    Online          
       SIB F2S 2/2 :    Online          
       SIB F2S 2/4 :    Online         
       SIB F2S 2/6 :    Online          
    PLANE  3:    Online           
       SIB F13 8   :    Online          
       SIB F13 9   :    Online          
       SIB F2S 3/0 :    Online          
       SIB F2S 3/2 :    Online          
       SIB F2S 3/4 :    Online          
       SIB F2S 3/6 :    Online          
    PLANE  4:    Spare           
       SIB F13 11  :    Online          
       SIB F13 12  :    Online          
       SIB F2S 4/0 :    Online          
       SIB F2S 4/2 :    Online          
       SIB F2S 4/4 :    Online          
       SIB F2S 4/6 :    Online          
    
    lcc1-re0:
    --------------------------------------------------------------------------
    Fabric Management SIB State:
    SIB    0:    Online           
    SIB    1:    Online           
    SIB    2:    Online           
    SIB    3:    Online           
    SIB    4:    Online           

    In this example, the TXP-F13 SIB resides in an active switching plane. You can take switching plane 2 offline by taking a corresponding TXP-F2 SIB in the same plane offline. If the replacement or maintenance procedure is to be performed on a component in a switching plane that is in the spare state, it is not necessary to take the switching plane offline.

  3. Take the switching plane offline by issuing the request chassis sib f2s slot slot-number offline command. For example:
    user@host> request chassis sib f2s slot 2/0 offline
    Offline initiated, use "show chassis sibs" to verify
    
  4. After you have finished the replacement or maintenance procedure, issue the request chassis sib f2 slot slot-number online command to put the switching plane into the spare state. For example:
    user@host> request chassis sib f2s slot 2/0 online
    Online initiated, use "show chassis sibs" to verify
    
  5. Issue the show chassis fabric plane detail command to confirm that the switching plane is in the spare state.
    user@host> show chassis fabric plane detail
    sfc0-re0:
    --------------------------------------------------------------------------
    Fabric Management PLANE State:
    PLANE  0:    Online           
       SIB F13 0   :    Online          
       SIB F13 1   :    Online          
       SIB F2S 0/0 :    Online          
       SIB F2S 0/2 :    Online          
       SIB F2S 0/4 :    Online          
       SIB F2S 0/6 :    Online          
    PLANE  1:    Spare           
       SIB F13 3   :    Online          
       SIB F13 4   :    Online          
       SIB F2S 1/0 :    Online          
       SIB F2S 1/2 :    Online          
       SIB F2S 1/4 :    Online          
       SIB F2S 1/6 :    Online          
    PLANE  2:    Online           
       SIB F13 6   :    Online           
       SIB F13 7   :    Online          
       SIB F2S 2/0 :    Online          
       SIB F2S 2/2 :    Online          
       SIB F2S 2/4 :    Online         
       SIB F2S 2/6 :    Online          
    PLANE  3:    Online           
       SIB F13 8   :    Online          
       SIB F13 9   :    Online          
       SIB F2S 3/0 :    Online          
       SIB F2S 3/2 :    Online          
       SIB F2S 3/4 :    Online          
       SIB F2S 3/6 :    Online          
    PLANE  4:    Online           
       SIB F13 11  :    Online          
       SIB F13 12  :    Online          
       SIB F2S 4/0 :    Online          
       SIB F2S 4/2 :    Online          
       SIB F2S 4/4 :    Online          
       SIB F2S 4/6 :    Online          
    
    lcc1-re0:
    --------------------------------------------------------------------------
    Fabric Management SIB State:
    SIB    0:    Online           
    SIB    1:    Online           
    SIB    2:    Online           
    SIB    3:    Online           
    SIB    4:    Online           
 

Related Documentation

  • T Series
  • Replacing a TXP-F13 SIB
  • Replacing a TXP-F2S SIB
  • Replacing a Fiber-Optic Array Cable
  • Cleaning Fiber-Optic Array Components with the Dry Cloth Cleaning Tool
 

Published: 2011-12-19

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|