Before removing a Switch Fabric and Routing Engine (SRE) module from an EX8208 switch, take the module offline.
The SRE module performs switching and system management functions in an EX8208 switch. Your switch can have either one or two SRE modules.
This topic describes:
To take an SRE module offline in a switch with two SRE modules:
user@switch> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority
Master (default) ...user@switch> request chassis routing-engine
master switchuser@switch> request system halt other-routing-engineuser@switch> request chassis cb offline
slot slot-numberwhere slot-number is either 0 (slot SRE0) or 1 (slot SRE1).
user@switch> show chassis environment
cbIf the state field in the command output shows that the module is offline, then it is safe to remove the SRE module.
To take the SRE module offline:
user@switch> request system haltThe RE module is gracefully halted but not powered off.
When a message appears confirming that the operating system has halted, it is safe to remove the SRE module. The Routing Engine might take up to 5 minutes to gracefully halt.