Home > Support > Technical Documentation > Replacing SRX5800 Services Gateway SPCs
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

Replacing SRX5800 Services Gateway SPCs

To replace an SPC, perform the following procedures:

  1. Removing an SRX5800 Services Gateway SPC
  2. Installing an SRX5800 Services Gateway SPC

Removing an SRX5800 Services Gateway SPC

An SPC weighs up to 13.1 lb (5.9 kg). Be prepared to accept its full weight.

To remove an SPC (see Figure 1):

  1. Have ready a replacement SPC or blank panel and an antistatic mat for the SPC. Also have ready rubber safety caps for each SPC you are removing that uses an optical interface.
  2. Attach an ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  3. Power-off the services gateway.
  4. Label the cables connected to each port on the SPC so that you can later reconnect the cables to the correct ports.
  5. Disconnect the cables from the SPC. If the SPC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap. Arrange the disconnected cables in the cable management system to prevent the cables from developing stress points.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

    Caution: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

    Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

    Caution: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

  6. Simultaneously turn both of the ejector handles counterclockwise to unseat the SPC.
  7. Grasp the handles and slide the SPC straight out of the card cage halfway.
  8. Place one hand around the front of the SPC and the other hand under it to support it. Slide the SPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.

    Caution: The weight of the SPC is concentrated in the back end. Be prepared to accept the full weight—up to 13.1 lb (5.9 kg)—as you slide the SPC out of the chassis.

    When the SPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.

    Do not stack SPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.

  9. If you are not reinstalling an SPC into the empty slot within a short time, install a blank panel over the slot to maintain proper airflow in the card cage.

Figure 1: Removing an SPC

Image g030220.gif

Installing an SRX5800 Services Gateway SPC

To install an SPC (see Figure 2):

  1. Attach an ESD grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  2. If you have not already done so, power off the device.
  3. Place the SPC on an antistatic mat or remove it from its electrostatic bag.
  4. Identify the slot on the services gateway where it will be installed.
  5. Verify that each fiber-optic transceiver is covered with a rubber safety cap. If it does not, cover the transceiver with a safety cap.
  6. Orient the SPC so that the faceplate faces you, the text on the card is right-side up, and the EMI strip is on the right-hand side.
  7. Lift the SPC into place and carefully align first the bottom and then the top of the card with the guides inside the card cage.
  8. Slide the SPC all the way into the card cage until you feel resistance.
  9. Grasp both ejector handles and rotate them clockwise simultaneously until the SPC is fully seated.
  10. If the SPC uses fiber-optic cable, remove the rubber safety cap from each transceiver and cable.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

  11. Insert the appropriate cables into the cable connector ports on each SPC (see Figure 3). Secure the cables so that they are not supporting their own weight. Place excess cable out of the way in a neatly coiled loop, using the cable management system. Placing fasteners on a loop helps to maintain its shape.

    Caution: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

    Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  12. Power-on the services gateway.
  13. Verify that the SPC is functioning correctly by issuing the show chassis fpc and show chassis fpc pic-status commands.

Figure 2: Installing an SPC

Image g030221.gif

Figure 3: Attaching a Cable to an SPC

Image g030233.gif

Published: 2011-03-29

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out