Installing an SRX5800 Services Gateway SPC
To install an SPC (see Figure 1):
- Attach an ESD grounding strap to your bare wrist,
and connect the strap to one of the ESD points on the chassis.
- If you have not already done so, power off the device.
- Place the SPC on an antistatic mat or remove it
from its electrostatic bag.
- Identify the slot on the services gateway where
it will be installed.
- Verify that each fiber-optic transceiver is covered
with a rubber safety cap. If it does not, cover the transceiver with
a safety cap.
- Orient the SPC so that the faceplate faces you, the text
on the card is right-side up, and the EMI strip is on the right-hand
side.
- Lift the SPC into place and carefully align first
the bottom and then the top of the card with the guides inside the
card cage.
- Slide the SPC all the way into the card cage until
you feel resistance.
- Grasp both ejector handles and rotate them clockwise
simultaneously until the SPC is fully seated.
- If the SPC uses fiber-optic cable, remove the rubber
safety cap from each transceiver and cable.
 | Warning:
Do not look directly into a fiber-optic
transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers
and fiber-optic cable connected to a transceiver emit laser light
that can damage your eyes. |
- Insert the appropriate cables into the cable connector
ports on each SPC (see Figure 2). Secure the cables so that they are not supporting their
own weight. Place excess cable out of the way in a neatly coiled loop,
using the cable management system. Placing fasteners on a loop helps
to maintain its shape.
 | Caution:
Do not let fiber-optic cable hang free from the connector.
Do not allow fastened loops of cable to dangle, which stresses the
cable at the fastening point. |
 | Caution:
Avoid bending fiber-optic cable beyond its minimum
bend radius. An arc smaller than a few inches in diameter can damage
the cable and cause problems that are difficult to diagnose. |
- Power-on the services gateway.
- Verify that the SPC is functioning correctly by
issuing the show chassis fpc and show chassis fpc
pic-status commands.
Figure 1: Installing an SPC
Figure 2: Attaching a Cable to an SPC