![]() | Note: Before you install one or more FPC4s in a T640 router that is not part of a routing matrix, you must replace each SIB in the router with a SIB version B. SIB version B is supported in Junos OS Release 7.3 and later. |
Standard SIBs and SIB version B cannot be installed in the same chassis at the same time, except during upgrade. To upgrade to standard SIB version B, you prepare the router by placing it into upgrade mode, then replace each standard SIB with a standard SIB version B.
![]() | Note: During the upgrade, the T640 router might experience some packet loss, depending on the operational environment. For more information, contact your customer support representative. |
To upgrade for each of the SIBs in the T640 router:
To prepare to upgrade from standard SIBs to standard SIB version B:
user@host# set chassis fabric upgrade-modeuser@host# commit synchronizeuser@host> show chassis sibsSlot State Uptime 0 Spare 255 days, 31 minutes, 12 seconds 1 Online 255 days, 31 minutes, 12 seconds 2 Online 255 days, 31 minutes, 12 seconds 3 Online 255 days, 31 minutes, 12 seconds 4 Online 255 days, 31 minutes, 12 seconds
Verify that four SIBs are in the Online state. If five SIBs are installed, verify that one SIB is in the Spare state. To bring a SIB online, issue the request chassis sib online operational mode command.
To replace the T640 standard SIBs with Standard SIB Version B, , perform the following procedures:
user@host> request chassis sib offline slot
0![]() | Note: When you bring an active SIB offline, the spare SIB becomes active and transitions to the Online state. |
![]() | Note: Ensure that the ejector handle tabs are properly mated inside their corresponding chassis slots before you tighten the captive screws on the ejector handles. You might have to close and open the handles a few times before the tabs catch the slots. |