Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Support
Technical Documentation
Content Explorer New
 
Enterprise MIBs
 
EOL Documentation
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > EX Series > EX8208 Hardware Documentation > Installing an SF Module in an EX8208 Switch
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

EX Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • EX8208
 
 

Related Documentation

  • EX Series
  • Removing an SF Module from an EX8208 Switch
  • Switch Fabric (SF) Module in an EX8208 Switch
  • SF Module LEDs in an EX8208 Switch
  • Field-Replaceable Units in an EX8208 Switch
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
EX Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
Enterprise Routing and Switching Certification Track
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Switching Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse EX Series Articles  Login required
  • Technical Bulletins for EX Series Login required
  • IOS to Junos Migration Tool Login required
Show All Show Fewer 
 
 

Installing an SF Module in an EX8208 Switch

You can install either zero Switch Fabric (SF) modules or one SF module in an EX8208 switch depending on the switch configuration you want to have. One SF module is included in the base configuration. See EX8208 Switch Configurations.

The SF module can be installed only in the slot labeled SF. The SF module is keyed so that it does not fit in any other slot in the chassis.

Note: Do not lift the SF module by holding the ejector levers. The levers cannot support the weight of the module. Lifting the module by the levers might bend the levers. Bent levers prevent the SF module from being properly seated in the chassis.

Before you begin installing an SF module in an EX8208 switch:

  • Ensure you understand how to prevent ESD damage. See Prevention of Electrostatic Discharge Damage.

Ensure that you have the following parts and tools available to install an SF module:

  • Electrostatic discharge (ESD) grounding strap
  • Phillips (+) screwdriver, number 2

To install an SF module (see Figure 1):

  1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
  2. If the slot has a cover panel on it, use the Phillips (+) screwdriver, number 2 to remove the two screws on each side of the cover panel. Save the cover panel for later use.
  3. Taking care not to touch the leads, pins, or solder connections, pull the SF module out from the bag.
  4. Pull both the ejector levers outwards, away from the faceplate of the SF module, until they go no further.
  5. Align the sides of the SF module with the guides inside the chassis.
  6. Ensuring that the module remains correctly aligned, slide the SF module into the chassis until you feel resistance.
  7. Push both the ejector levers towards the faceplate of the SF module until the levers are flush against the faceplate and are fully engaged.
  8. Tighten the screws on each side of the SF module by turning them clockwise using the Phillips (+) screwdriver, number 2. Ensure that the SF module is fully seated in the chassis.
  9. Verify that the SF module is installed correctly and functioning normally by checking the LEDs on the faceplate of the SF module. The ST LED and SF LED should be lit steady green a few minutes after the SF module is installed.

    If the ST LED is unlit, check whether there are enough power supplies installed. See Calculating Power Requirements for an EX8208 Switch. If more power supplies are needed, install additional power supplies. See Installing an AC Power Supply in an EX8200 Switch. If there are enough power supplies in the switch, remove and install the SF module again. See Removing an SF Module from an EX8208 Switch.

    If the ST LED or the SF LED is lit steady yellow, the SF module has failed. Remove the SF module and install a new one. See Removing an SF Module from an EX8208 Switch.

Figure 1: Installing an SF Module in an EX8208 Switch

Image g020558.gif

 

Related Documentation

  • EX Series
  • Removing an SF Module from an EX8208 Switch
  • Switch Fabric (SF) Module in an EX8208 Switch
  • SF Module LEDs in an EX8208 Switch
  • Field-Replaceable Units in an EX8208 Switch
 

Published: 2011-02-14

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out