Removing a QFX3100 Director Device from a Rack or Cabinet
If you need to relocate an installed QFX3100 Director device,
use the procedure described in this topic. (The remainder of this
topic uses “rack” to mean “rack or cabinet.”
)
 | Note:
When you remove multiple devices from a rack, remove the
device in the top of the rack first and proceed to remove the rest
of the devices from top to bottom. |
Before removing a QFX3100 Director device
from a rack:
- Ensure that the rack is stable and secured to the building.
- Ensure that there is enough space to place the removed
QFX3100 Director device in its new location and along the path to
the new location.
- Read General Safety Guidelines and Warnings.
- Ensure that the QFX3100 Director device has been safely
powered off and that you have unplugged (disconnected)
the power cords.
- Ensure that you have disconnected any cables or wires
attached to the QFX3100 Director device ports.
Ensure that you have the following parts and tools available:
- A Phillips (+) screwdriver, number 2 or number 3, depending
on the size of your rack mounting screws, for mounting the QFX3100
Director device on the rack.
To remove a QFX3100 Director device from a rack or cabinet:
- Use the screwdriver to remove the mounting screws that
attach the chassis front-mounting brackets to the rack or cabinet.
- Place the removed screws in a labeled bag. You will need
them when you reinstall the chassis.
- Lift the QFX3100 Director device from the rack or cabinet
and transport it to your desired new location.
Published: 2012-03-23