Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Support
Technical Documentation
Content Explorer New
 
Enterprise MIBs
 
EOL Documentation
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > M Series Routers > M7i Router Hardware > Powering on the M7i Router
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

M Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • M7i Routers
 
 

Related Documentation

  • M Series
  • Troubleshooting the M7i Power System When the LED on One M7i Power Supply Is Off
  • Troubleshooting the M7i Power System When the LEDs on All M7i Power Supplies Are Blinking or Off
  • General Electrical Safety Guidelines and Electrical Codes for M Series, MX Series, and T Series Routers
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
M Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
M Series Certification
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Security Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse M Series Articles  Login required
  • Technical Bulletins for M Series Login required
  • IOS to Junos Migration Tool Login required
  • ScreenOS to Junos software with enhanced services Migration Tool Login required
Show All Show Fewer 
 
 

Powering on the M7i Router

To power on the router:

  1. Verify that the power supplies are fully inserted in the chassis and the thumbscrews on their faceplates are tightened.
  2. For each power supply on an AC-powered router, verify that the ends of the power cord are firmly plugged into the appliance inlet on the power supply faceplate and the external power source receptacle.

    For each power supply on a DC-powered router, verify that the source DC power cables are connected to the appropriate terminal on the power supply faceplate: the positive (+) source cable to the return terminal (labeled RTN) and the negative (–) source cable to the input terminal (labeled –48V).

  3. Verify that an external management device is connected to one of the Routing Engine ports on the Routing Engine (AUX/MODEM, CONSOLE, or MGMT). For more information on connecting management devices, see Connecting the M7i Router to Management and Alarm Devices.
  4. Turn on the power to the external management device.
  5. Press the power switch for one power supply to the ON ( | ) position. On both AC and DC power supplies, the switch is located on the power supply faceplate.
  6. Verify that the OUTPUT OK LED lights steadily.

    Note: After powering off a power supply, wait at least 60 seconds before turning it back on. After powering on a power supply, wait at least 60 seconds before turning it off.

    If the router is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence. If the Routing Engine finishes booting and you need to power off the router again, see Powering Off the M7i Router.

    After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LED on the power supply, the command display output, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.

  7. Press the power switch for the second power supply to the ON ( | ) position and verify that the OUTPUT OK LED lights steadily. If the LED does not light after 60 seconds, verify that the power supply is properly inserted into the chassis and repeat the cable installation procedures described in Connecting Power to an AC-Powered M7i Router or Connecting Power to a DC-Powered Router.
  8. On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.
 

Related Documentation

  • M Series
  • Troubleshooting the M7i Power System When the LED on One M7i Power Supply Is Off
  • Troubleshooting the M7i Power System When the LEDs on All M7i Power Supplies Are Blinking or Off
  • General Electrical Safety Guidelines and Electrical Codes for M Series, MX Series, and T Series Routers
 

Published: 2010-10-28

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out