Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Support
Technical Documentation
Content Explorer New
 
Enterprise MIBs
 
EOL Documentation
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > M Series Routers > M7i Router Hardware > Installing an M7i AC Power Cord
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

M Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • M7i Routers
 
 

Related Documentation

  • M Series
  • M7i AC Power Electrical Safety Guidelines and Warnings
  • M7i Router AC Power Supply Specifications
  • Replacing an M7i AC Power Supply
  • Removing an M7i AC Power Cord
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
M Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
M Series Certification
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Security Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse M Series Articles  Login required
  • Technical Bulletins for M Series Login required
  • IOS to Junos Migration Tool Login required
  • ScreenOS to Junos software with enhanced services Migration Tool Login required
Show All Show Fewer 
 
 

Installing an M7i AC Power Cord

To install an AC power cord:

  1. Locate a replacement power cord with the type of plug appropriate for your geographical location (see M7i Router AC Power, Connection, and Power Cord Specifications).
  2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis.
  3. Insert the appliance coupler end of the replacement power cord into the appliance inlet on the power supply faceplate and insert the plug into an AC power source receptacle.
  4. Verify that the power cord does not block access to router components or drape where people could trip on it.
  5. Press the power switch on the power supply faceplate to the ON ( |) position.

    Note: After powering on a power supply, wait at least 60 seconds before turning it off.

  6. If you have only one power supply or the router is completely powered off when you power on the power supply, the Routing Engine boots as the power supply completes its startup sequence.

    On the external management device connected to the Routing Engine, monitor the startup process to verify that the system has booted properly.

    Note: If the Routing Engine finishes booting and you need to power off the router again, see Powering Off the M7i Router. After powering off a power supply, wait at least 60 seconds before turning it back on.

  7. Check the LEDs on the power supply faceplate. When the power supply has powered on successfully, the green OUTPUT OK LED lights steadily.

    After a power supply is powered on, it can take up to 60 seconds for status indicators—such as the output status LED on the power supply, the command display output, and messages on the LED display on the craft interface—to indicate that the power supply is functioning normally. Ignore error indicators that appear during the first 60 seconds.

    If the LEDs are not lit in the appropriate pattern after 60 seconds, repeat the procedures to replace the AC power cord.

 

Related Documentation

  • M Series
  • M7i AC Power Electrical Safety Guidelines and Warnings
  • M7i Router AC Power Supply Specifications
  • Replacing an M7i AC Power Supply
  • Removing an M7i AC Power Cord
 

Published: 2010-10-28

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out