You can disconnect power from the JCS1200 platform by powering off the Routing Engines and disconnecting the JCS1200 platform from the power source.
To disconnect power from the JCS1200 platform:
![]() | Note: After you disconnect the JCS1200 platform from power, wait at least 5 seconds before you connect the JCS1200 platform to power again. |
![]() | Caution: This device does not provide a power control button. Powering off Routing Engines or removing power modules and switch modules does not turn off electrical current to the device. The device also might have more than one power cord. To remove all electrical current from the product, make sure that all power cords are disconnected from the power source. ![]() |
![]() | Caution: Only trained service personnel other than Juniper Networks service technicians are authorized to make the connections to and disconnections from the –48 volt DC power source. Juniper Networks service technicians are not certified or authorized to install or remove the –48 volt power cable. The customer is responsible for ensuring that only trained service personnel install or remove the –48 volt power cable. |
Figure 1: DC Power Terminal Connectors on the JCS1200 Platform

![]() | Caution: This device does not provide a power control button. Powering off Routing Engines or removing power modules and switch modules does not turn off electrical current to the device. The device also might have more than one power cord. To remove all electrical current from the product, make sure that all power cords are disconnected from the power source. ![]() |