Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Support
Technical Documentation
Content Explorer New
 
Enterprise MIBs
 
EOL Documentation
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > MX Series Routers > MX480 Router Hardware > Replacing a Cable on an MX480 DPC, MPC, MIC, or PIC
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • MX Series
  • Preventing Electrostatic Discharge Damage to an MX480 Router
  • Maintaining Cables That Connect to MX480 DPCs, MPCs, MICs, or PICs
 

Replacing a Cable on an MX480 DPC, MPC, MIC, or PIC

  1. Removing a Cable on an MX480 DPC, MPC, MIC, or PIC
  2. Installing a Cable on an MX480 DPC, MPC, MIC, or PIC

Removing a Cable on an MX480 DPC, MPC, MIC, or PIC

Removing and installing cables on a DPC, MPC, MIC, or PIC does not affect router function.

To remove a cable:

  1. Have ready a rubber safety cap for each fiber-optic cable and transceiver.
  2. If removing all cables connected to the component, use one of the following methods to take the component offline:
    • To take a DPC or an MPC offline:
      • Press and hold the corresponding online button on the craft interface. The green OK LED next to the button begins to blink. Hold the button down until the LED goes off.
      • Issue the following CLI command:
        user@host>request chassis fpc slot slot-number offline

        For more information about the command, see the Junos OS System Basics and Services Command Reference PDF Document.

    • To take a PIC offline:
      • Press the online/offline button on the PIC. For a PIC installed in an FPC3, use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the PIC LED goes off (about 5 seconds).
      • Issue the following CLI command:
        user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot offline

        For more information about the command, see the Junos OS System Basics and Services Command Reference PDF Document.

    • To take a MIC offline:
      • Press the online/offline button on the MIC. Use a narrow-ended tool that fits inside the opening that leads to the button. Press and hold the button until the MIC LED goes off (about 5 seconds).
      • Issue the following CLI command:
        user@host> request chassis mic fpc-slot mpc-slot pic-slot mic-slot offline

        For more information about the command, see the Junos OS System Basics and Services Command Reference PDF Document.

  3. Disconnect the cable from the cable connector port. If the component uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

    Caution: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

  4. Remove the cable from the cable management brackets.
  5. Disconnect the cable from the destination port.

Installing a Cable on an MX480 DPC, MPC, MIC, or PIC

To install a cable:

  1. Have ready a length of the type of cable used by the DPC, MPC, MIC, or PIC. For cable specifications, see the MX Series 3D Universal Edge Routers Line Card Guide PDF Document.
  2. If the cable connector port is covered by a rubber safety plug, remove the plug.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

    Caution: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

  3. Insert the cable connector into the cable connector port on the component faceplate.
  4. Arrange the cable in the cable management brackets to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop. Placing fasteners on the loop helps to maintain its shape.

    Caution: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

    Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  5. Insert the other end of the cable into the destination port.
  6. Repeat the previous steps for any additional cables.
  7. If the component is offline (its failure indicator LED is lit), use one of the following methods to bring the it online:
    • To bring a DPC or an MPC online:
      • Press and hold the corresponding online button on the craft interface until the green OK LED next to the button lights steadily, in about 5 seconds.
      • Issue the following CLI command:
        user@host>request chassis fpc slot slot-number online

        For more information about the command, see the Junos OS System Basics and Services Command Reference PDF Document.

    • To bring a PIC online:
      • Press the PIC offline/online button until the PIC LED lights green. For a PIC installed in an FPC2 or FPC3, use a narrow-ended tool that fits inside the opening that leads to the button.
      • Issue the following CLI command:
        user@host>request chassis pic fpc-slot fpc-slot pic-slot pic-slot online

        For more information about the command, see the Junos OS System Basics and Services Command Reference PDF Document.

    • To bring a MIC online:
      • Press the MIC offline/online button until the MIC LED lights green.
      • Issue the following CLI command:
        user@host>request chassis mic fpc-slot mpc-slot pic-slot mic-slot online

        For more information about the command, see the Junos OS System Basics and Services Command Reference PDF Document.

    The normal functioning indicator LED confirms that the component is online. You can also verify correct DPC or MPC functioning by issuing the show chassis fpc command or correct MIC or the PIC functioning by issuing the show chassis fpc pic-status command.

 

Related Documentation

  • MX Series
  • Preventing Electrostatic Discharge Damage to an MX480 Router
  • Maintaining Cables That Connect to MX480 DPCs, MPCs, MICs, or PICs
 

Published: 2011-09-08

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out