Home > Support > Technical Documentation > MX Series Routers > MX240 Router Hardware > Replacing an MX240 MPC
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

MX Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • MX240 Routers
 
 

Related Documentation

  • MX Series
  • MX240 Modular Port Concentrator (MPC) Description
  • Maintaining MX240 MPCs
  • Replacing an MX240 MIC
  • MX240 MPC Serial Number Label
  • Preventing Electrostatic Discharge Damage to an MX240 Router
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
MX Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
Certification
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Security Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse MX Series Articles  Login required
  • Technical Bulletins for MX Series Login required
  • IOS to Junos Migration Tool Login required
  • ScreenOS to Junos software with enhanced services Migration Tool Login required
Show All Show Fewer 
 
 

Replacing an MX240 MPC

  1. Removing an MX240 MPC
  2. Installing an MX240 MPC

Removing an MX240 MPC

When you remove an MPC, the router continues to function, although the MIC interfaces installed on the MPC being removed no longer function.

An MPC installs horizontally in the front of the router. The MPCs are hot-insertable and hot-removable. A fully configured MPC can weigh up to 18.35 lb (8.3 kg). Be prepared to accept its full weight.

To remove an MPC (see Figure 1):

  1. Have ready a replacement MPC or DPC blank panel and an antistatic mat for the MPC. Also have ready rubber safety caps for each MIC using an optical interface on the MPC that you are removing.
  2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  3. Label the cables connected to each MIC on the MPC so that you can later reconnect the cables to the correct MICs.
  4. Use one of the following methods to take the MPC offline:
    • Press and hold the corresponding online button on the craft interface. The green OK/FAIL LED next to the button begins to blink. Hold the button down until the LED goes off.
    • Issue the following CLI command:

      user@host>request chassis fpc slot slot-number offline

      For more information about the command, see the Junos OS System Basics and Services Command Reference.

  5. Disconnect the cables from the MICs installed in the MPC.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

    Caution: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

    Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  6. If a MIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.
  7. Simultaneously turn both the ejector handles counterclockwise to unseat the MPC.
  8. Grasp the handles and slide the MPC straight out of the card cage halfway.
  9. Place one hand around the front of the MPC (the MIC housing) and the other hand under it to support it. Slide the MPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.

    Caution: The weight of the MPC is concentrated in the back end. Be prepared to accept the full weight—up to 18.35 lb (8.3 kg)—as you slide the MPC out of the chassis.

    When the MPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.

    Do not stack MPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.

  10. If necessary, remove each installed MIC from the MPC.
  11. After you remove each MIC, immediately place it on an antistatic mat or in an electrostatic bag.
  12. If you are not reinstalling an MPC into the emptied line card slots within a short time, install a blank DPC panel over each slot to maintain proper airflow in the card cage.

    Caution: After removing an MPC from the chassis, wait at least 30 seconds before reinserting it or inserting an MPC into a different slot.

Figure 1: Removing an MPC

Image g004917.gif

Installing an MX240 MPC

An MPC installs horizontally in the front of the router. The MPCs are hot-insertable and hot-removable. A fully configured MPC can weigh up to 18.35 lb (8.3 kg). Be prepared to accept its full weight.

To install an MPC (see Figure 2):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  2. Place the MPC on an antistatic mat.
  3. Take each MIC to be installed in the replacement MPC out of its electrostatic bag and identify the slot on the MPC where it will be connected.
  4. Verify that each fiber-optic MIC has a rubber safety cap covering the MIC transceiver. If it does not, cover the transceiver with a safety cap.
  5. Install each MIC into the appropriate slot on the MPC.
  6. Locate the slot in the card cage in which you plan to install the MPC.
  7. Orient the MPC so that the faceplate faces you.
  8. Lift the MPC into place and carefully align the sides of the MPC with the guides inside the card cage.

    Caution: When the MPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.

  9. Slide the MPC all the way into the card cage until you feel resistance.
  10. Grasp both ejector handles and rotate them clockwise simultaneously until the MPC is fully seated.
  11. If any of the MICs on the MPC connect to fiber-optic cable, remove the rubber safety cap from each transceiver and cable.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

  12. Insert the appropriate cable into the cable connector ports on each MIC on the MPC. Secure the cables so that they are not supporting their own weight. Placing fasteners on a loop helps to maintain its shape.

    Caution: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

    Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  13. Use one of the following methods to bring the MPC online:
    • Press and hold the corresponding MPC online button on the craft interface until the green OK/FAIL LED next to the button lights steadily, in about 5 seconds.
    • Issue the following CLI command:

      user@host>request chassis fpc slot slot-number online

      For more information about the command, see the Junos OS System Basics and Services Command Reference.

    Caution: After the OK/FAIL LED lights steadily, wait at least 30 seconds before removing the MPC again, removing an MPC from a different slot, or inserting an MPC in a different slot.

You can also verify correct MPC and MIC functioning by issuing the show chassis fpc and show chassis fpc pic-status commands described in Maintaining MX240 MPCs and Maintaining MX240 MICs.

Figure 2: Installing an MPC

Image g004913.gif
 

Related Documentation

  • MX Series
  • MX240 Modular Port Concentrator (MPC) Description
  • Maintaining MX240 MPCs
  • Replacing an MX240 MIC
  • MX240 MPC Serial Number Label
  • Preventing Electrostatic Discharge Damage to an MX240 Router
 

Published: 2011-02-25

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out