Replacing a JCS1200 Management Module or Module Filler
Removing a JCS1200 Management Module or Module Filler
Figure 1 shows how
to remove and install a management module.
Figure 1: Removing and Installing
a JCS1200 Management Module
When you remove a management module, keep in mind the following:
- These instructions assume that the JCS1200 platform
is connected to power.
- If you are replacing the only management module in the
platform and the management module is functioning, save the configuration
file before you proceed. For information about saving and restoring
a configuration file, see the Junos OS Protected System Domain Configuration Guide.
- If you have just installed a second management module
in the platform, do not remove the first (primary) management module
for up to 45 minutes; the second (redundant) management module needs
the time to receive initial status information and firmware from the
management module.
To remove a management module or module filler
(see Figure 1):
- Attach an electrostatic discharge (ESD) grounding strap
to your bare wrist, and connect the strap to one of the ESD points
on the chassis.
- Pull the management module release handle
to the open position. The module moves out of the bay approximately
0.25 in. (0.6 cm).
- Slide the management module out of the bay.
Installing a JCS1200 Management Module or Module Filler
Figure 2 shows how
to remove and install a management module.
Figure 2: Removing and Installing
a JCS1200 Management Module
To install a management module or module filler
(see Figure 2):
- Attach an electrostatic discharge (ESD) grounding strap
to your bare wrist, and connect the strap to one of the ESD points
on the chassis.
- Remove the management module filler, if
one is installed.
- Remove the management module interposer filler
tray, if one is installed.
- Install the management module interposer, if it
is not already installed.
- Make sure that the release handle on the management
module is in the open position.
- Slide the management module into the management
module bay until it stops.
- Push the management module release handle to the
closed position.
- Connect any cables to the management module.
- If the platform is connected to power, make sure
that the OK LED on the management module is lit. If the management
module is redundant, wait at least 45 minutes for the modules to copy
the configuration data before you make any changes to the management
module configuration.