Installing the Lockable Front Doors on a QFX3008-I Interconnect
Device
The lockable front doors cover the front card cage. A captive
thumbscrew at the base where the doors meet secures the doors in a
closed position. You can also lock these doors in the closed position
to prevent cables, transceivers, or front cards from being removed.
You must provide the lock. The lockable front doors are an optional
field-replaceable unit (FRU).
Before you begin, ensure that you have the
following parts and tools available to install the lockable front
doors on a QFX3008-I Interconnect device:
- Electrostatic discharge (ESD) grounding strap
- Phillips (+) screwdriver, number 1
- Eight mounting screws—These screws are already installed
on the chassis, in each corner of the top and bottom front card cage
ejector lever receptacle bars.
To install the lockable front doors on a QFX3008-I Interconnect
device (see Figure 1):
- Attach the ESD grounding strap to your bare wrist, and
connect the strap to the ESD point on the chassis.
- Remove the two screws
at each corner of the top and bottom front card cage ejector lever
receptacle bars. The screws are located in the inset portion of the
bar.
- Place one of the doors on the chassis, aligning the holes
on its faceplate with the mounting holes on the chassis.
- Install the four
mounting screws, tightening them by turning them clockwise using the
Phillips (+) screwdriver, number 1.
- Repeat Step 2 through Step 4 for the other door.
 | Note:
The doors must be in the open position to remove or install
the bottom fan tray and front panel display. |
Figure 1: Installing the
Lockable Front Doors on a QFX3008-I Interconnect Device
Published: 2012-03-23