Replacing an FPC in an M40e Router
FPCs are hot-removable and
hot-insertable, as described in M40e Field-Replaceable Units (FRUs). When you remove an FPC, forwarding operations
halt for about 200 ms while the Packet Forwarding Engine flushes
the shared memory buffers on the remaining FPCs.
Removing an FPC in an M40e Router
To remove an FPC (see Figure 1):
- Place an antistatic mat on a flat, stable surface
to receive the FPC. If you are removing PICs from the FPC, prepare
an antistatic mat or electrostatic bag for each one. If any of the
PICs on the FPC use fiber-optic cable, have ready a rubber safety
cap for each transceiver and cable.
- Attach an electrostatic discharge (ESD) grounding strap to your
bare wrist, and connect the strap to one of the ESD points on the
chassis. For more information about ESD, see Preventing Electrostatic Discharge Damage to an M Series, MX Series, or T Series Router.
- Label the cables connected to each PIC on the
FPC so that you can later reconnect the cables to the correct PICs.
- Use one of the following methods to take the FPC
offline:
- Disconnect the cables from the PICs installed
in the FPC. If a PIC uses fiber-optic cable, immediately cover each
transceiver and the end of each cable with a rubber safety cap. Arrange
the disconnected cables in the cable management system, to prevent
the cables from developing stress points.
 | Warning:
Do not look directly into a fiber-optic
transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers
and fiber-optic cable connected to a transceiver emit laser light
that can damage your eyes. |
 | Caution:
Do not leave a fiber-optic transceiver uncovered except
when inserting or removing cable. The safety cap keeps the port clean
and prevents accidental exposure to laser light. |
 | Caution:
Avoid bending fiber-optic cable beyond its minimum
bend radius. An arc smaller than a few inches in diameter can damage
the cable and cause problems that are difficult to diagnose. |
- If you are transferring any PICs to a different FPC, remove
them while the FPC is still installed:
- Unscrew the thumbscrews at the top and bottom of the PIC
faceplate simultaneously and at about the same rate (unscrewing the
two screws alternately or at very different rates can cause the PIC
to become lodged in the FPC slot, making it difficult to turn the
screws).
- Slide the PIC out of the slot and immediately place it
on an antistatic mat or in an electrostatic bag.
- Loosen the thumbscrew at each end of the FPC, using
a Phillips screwdriver if necessary.
- Pull the ends of the ejector levers, which are
adjacent to the thumbscrews, away from the face of the FPC until they
are nearly perpendicular to it.
- Grasp the top and bottom flanges of the card carrier
and slide the FPC about halfway out of the card cage.
- Place one hand around the front of the FPC (the
PIC housing) and the other hand under it to support it. Slide the
FPC completely out of the chassis, and place it on the antistatic
mat or in the electrostatic bag.
 | Caution:
The weight of the FPC is concentrated in the back end.
Be prepared to accept the full weight—up to 15 lb (6.8 kg)—as
you slide the FPC out of the chassis. When the FPC is out of the chassis, do not hold it by the ejector levers,
bus bars, or edge connectors. They cannot support its weight. Do not stack FPCs on top of one another after removal. Place
each one individually in an electrostatic bag or on its own antistatic
mat on a flat, stable surface. |
- If you are not reinstalling a FPC into the emptied
FPC slot within a short time, install a blank FPC panel over the slot
to maintain proper airflow in the FPC card cage.
 | Caution:
After removing an FPC from the chassis, wait at least
30 seconds before reinserting it, removing an FPC from a different
slot, or inserting an FPC into a different slot. |
Figure 1: Removing an FPC from an
M40e Router
Installing an FPC in an M40e Router
To install an FPC (see Figure 2 and Figure 3):
- Attach an electrostatic discharge (ESD) grounding
strap to your bare wrist, and connect the strap to one of the ESD
points on the chassis. For more information about ESD, see Preventing Electrostatic Discharge Damage to an M Series, MX Series, or T Series Router.
- Verify that the ends of the ejector levers, which
are located at each end of the FPC, are pushed outward, nearly perpendicular
to the face of the FPC.
- Grasp the front of the FPC with one hand and place
the other hand under the FPC to support it.
 | Caution:
When the FPC is out of the chassis, do not hold it
by the ejector levers, bus bars, or edge connectors. They cannot
support its weight. |
- Align the rear bottom corners of the FPC with the
guides at the bottom of the FPC slot. Slide the FPC into the card
cage until it contacts the midplane.
- Push the ends of the ejector levers inward until
they are nearly flush with the face of the FPC.
- Tighten the thumbscrew at each end of the FPC to
seat the FPC securely in the chassis.
- For each different PIC you install in the FPC:
- If the PIC uses fiber-optic cable, verify that there is
a rubber safety cap over each transceiver on the faceplate. Install
a cap if necessary.
- Slide the PIC into a slot in the FPC, aligning the notches
in the connector at the rear of the PIC with the notches in the FPC
slot and then firmly pushing the PIC into place.
 | Caution:
Insert the PIC straight into the FPC slot to avoid
damaging the components on the bottom of the PIC. |
- Tighten the thumbscrews at the ends of the PIC faceplate
simultaneously and at about the same rate (tightening the two screws
alternately or at very different rates can cause the PIC to become
lodged in the FPC slot, making it difficult to turn the screws). Verify
that the PIC is seated properly.
- If any of the PICs on the FPC connect to fiber-optic
cable, remove the rubber safety cap from each transceiver and cable.
 | Warning:
Do not look directly into a fiber-optic
transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers
and fiber-optic cable connected to a transceiver emit laser light
that can damage your eyes. |
- Insert the appropriate cable into the cable connector
ports on each PIC on the FPC. Secure the cables so that they are not
supporting their own weight. Place excess cable out of the way in
a neatly coiled loop, using the cable management system. Placing fasteners
on a loop helps to maintain its shape.
 | Caution:
Do not let fiber-optic cable hang free from the connector.
Do not allow fastened loops of cable to dangle, which stresses the
cable at the fastening point. |
 | Caution:
Avoid bending fiber-optic cable beyond its minimum
bend radius. An arc smaller than a few inches in diameter can damage
the cable and cause problems that are difficult to diagnose. |
- Use one of the following methods to bring the FPC
online:
 | Caution:
After the OK LED lights steadily, wait at
least 30 seconds before removing the FPC again, removing an FPC from
a different slot, or inserting an FPC in a different slot. |
You can also verify correct FPC and PIC functioning by issuing
the show chassis fpc and show chassis fpc
pic-status commands described inMaintaining M40e FPCs and Maintaining M40e PICs and PIC Cables.
Figure 2: Installing an FPC in an
M40e Router
Figure 3: Connecting Fiber-Optic Cable
to a PIC in an M40e Router
Published: 2010-10-28