Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Support
Technical Documentation
Content Explorer New
 
Enterprise MIBs
 
EOL Documentation
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > SRX Series Services Gateways > SRX5600 > Replacing SRX5600 Services Gateway Flex IOCs
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

Replacing SRX5600 Services Gateway Flex IOCs

To replace a Flex IOC, perform the following procedures:

  1. Removing an SRX5600 Services Gateway Flex IOC
  2. Installing an SRX5600 Services Gateway Flex IOC

Removing an SRX5600 Services Gateway Flex IOC

A Flex IOC weighs up to 13.1 lb (5.9 kg). Be prepared to accept the full weight of the card as you remove it.

To remove a Flex IOC (see Figure 1):

  1. Have ready a replacement card or blank panel and an antistatic mat for the Flex IOC.
  2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  3. Use one of the following methods to take the Flex IOC offline:
    • Press and hold the corresponding online button on the craft interface. The green OK LED next to the button begins to blink. Hold the button down until the LED goes off.
    • Issue the following CLI command:
      user@host>request chassis fpc slot slot-number offline

      For more information about the command, see the Junos OS System Basics and Services Command Reference.

  4. If you have not already done so, remove the port modules installed in the Flex IOC.
  5. Simultaneously turn both of the ejector handles counterclockwise to unseat the Flex IOC.
  6. Grasp the handles and slide the Flex IOC straight out of the card cage halfway.
  7. Place one hand around the front of the Flex IOC and the other hand under it to support it. Slide the Flex IOC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.

    Caution: The weight of the Flex IOC is concentrated in the back end. Be prepared to accept the full weight—up to 13.1 lb (5.9 kg)—as you slide the Flex IOC out of the chassis.

    When the Flex IOC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.

    Do not stack Flex IOCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.

  8. If you are not reinstalling a replacement card into the empty slot within a short time, install a blank panel over the slot to maintain proper airflow in the card cage.

    Caution: After removing an IOC from the chassis, wait at least 30 seconds before reinserting it, removing an IOC from a different slot, or inserting an IOC into a different slot.

Figure 1: Removing a Flex IOC

Image g030277.gif

Installing an SRX5600 Services Gateway Flex IOC

Note: Your services gateway must be running Junos OS Release 9.5R1 or later in order to recognize Flex IOCs and port modules.

To install a Flex IOC (see Figure 2):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  2. Place the Flex IOC on an antistatic mat or remove it from its electrostatic bag.
  3. Identify the slot on the services gateway where you will install the Flex IOC.
  4. If you have not already done so, remove the blank panel from the slot where you are installing the Flex IOC.
  5. Orient the Flex IOC so that the faceplate faces you, the text on the card is right-side up, and the EMI strip is on the right-hand side.
  6. Lift the Flex IOC into place and carefully alignthe right and left edges of the card with the guides inside the card cage.
  7. Slide the Flex IOC all the way into the card cage until you feel resistance.

    Figure 2: Installing a Flex IOC

    Image g030276.gif
  8. Grasp both ejector handles and rotate them clockwise simultaneously until the Flex IOC is fully seated.
  9. Use one of the following methods to bring the Flex IOC online:
    • Press and hold the corresponding online button on the craft interface until the green OK LED next to the button lights steadily, in about 5 seconds.
    • Issue the following CLI command:
      user@host>request chassis fpc slot slot-number online

      For more information about the command, see the Junos OS System Basics and Services Command Reference.

    Caution: After the OK LED turns green, wait at least 30 seconds before removing the card again, removing a card from a different slot, or inserting a card in a different slot.

Published: 2011-03-29

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out