Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Support
Technical Documentation
Content Explorer New
 
Enterprise MIBs
 
EOL Documentation
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > MX Series Routers > MX240 Router Hardware > Replacing an MX240 DPC
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

MX Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • MX240 Routers
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
MX Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
Certification
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Security Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse MX Series Articles  Login required
  • Technical Bulletins for MX Series Login required
  • IOS to Junos Migration Tool Login required
  • ScreenOS to Junos software with enhanced services Migration Tool Login required
Show All Show Fewer 
 
 

Replacing an MX240 DPC

  1. Removing an MX240 DPC
  2. Installing an MX240 DPC

Removing an MX240 DPC

A DPC weighs up to 13.1 lb (5.9 kg). Be prepared to accept its full weight.

To remove a DPC (see Figure 1):

  1. Have ready a replacement DPC or DPC blank panel and an antistatic mat for the DPC. Also have ready rubber safety caps for each DPC you are removing that uses an optical interface.
  2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  3. Label the cables connected to each port on the DPC so that you can later reconnect the cables to the correct ports.
  4. Use one of the following methods to take the DPC offline:
    • Press and hold the corresponding DPC online button on the craft interface. The green OK LED next to the button begins to blink. Hold the button down until the LED goes off.
    • Issue the following CLI command:

      user@host>request chassis fpc slot slot-number offline

      For more information about the command, see the Junos OS System Basics and Services Command Reference.

  5. Disconnect the cables from the DPC.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

    Caution: Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

    Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  6. Immediately cover each optical transceiver and the end of each fiber-optic cable with a rubber safety cap.
  7. Arrange the disconnected cables to prevent the cables from developing stress points.
  8. Simultaneously turn both of the ejector handles counterclockwise to unseat the DPC.
  9. Grasp the handles and slide the DPC straight out of the card cage halfway.
  10. Place one hand around the front of the DPC and the other hand under it to support it. Slide the DPC completely out of the chassis, and place it on the antistatic mat or in the electrostatic bag.

    Caution: The weight of the DPC is concentrated in the back end. Be prepared to accept the full weight—up to 13.1 lb (5.9 kg)—as you slide the DPC out of the chassis.

    When the DPC is out of the chassis, do not hold it by the ejector handles, bus bars, or edge connectors. They cannot support its weight.

    Do not stack DPCs on top of one another after removal. Place each one individually in an electrostatic bag or on its own antistatic mat on a flat, stable surface.

  11. If you are not reinstalling a DPC into the emptied DPC slot within a short time, install a blank DPC panel over the slot to maintain proper airflow in the DPC card cage.

    Caution: After removing a DPC from the chassis, wait at least 30 seconds before reinserting it, removing a DPC from a different slot, or inserting a DPC into a different slot.

Figure 1: Removing a DPC

Image g004330.gif

Installing an MX240 DPC

A DPC weighs up to 14.5 lb (6.6 kg). Be prepared to accept its full weight.

To install a DPC (see Figure 2):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
  2. Place the DPC on an antistatic mat, or remove it from its electrostatic bag.
  3. Identify the slot on the router where it will be installed.
  4. Verify that each fiber-optic transceiver is covered with a rubber safety cap. If it does not, cover the transceiver with a safety cap.
  5. Orient the DPC so that the faceplate faces you.
  6. Lift the DPC into place, and carefully align the sides of the DPC with the guides inside the card cage.
  7. Slide the DPC all the way into the card cage until you feel resistance.
  8. Grasp both ejector handles, and rotate them clockwise simultaneously until the DPC is fully seated.
  9. Remove the rubber safety cap from each fiber-optic transceiver and cable.

    Warning: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.

  10. Insert the cables into the cable connector ports on each DPC (see Figure 3).
  11. Arrange the cable to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop.

    Caution: Do not let fiber-optic cable hang free from the connector. Do not allow fastened loops of cable to dangle, which stresses the cable at the fastening point.

    Caution: Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  12. Use one of the following methods to bring the DPC online:
    • Press and hold the corresponding DPC online button on the craft interface until the green OK LED next to the button lights steadily, in about 5 seconds.
    • Issue the following CLI command:

      user@host>request chassis fpc slot slot-number online

      For more information about the command, see the Junos OS System Basics and Services Command Reference.

    Caution: After the OK LED turns green, wait at least 30 seconds before removing the DPC again, removing a DPC from a different slot, or inserting a DPC in a different slot.

You can also verify that the DPC is functioning correctly by issuing the show chassis fpc and show chassis fpc pic-status commands.

Figure 2: Installing a DPC

Image g004331.gif

Figure 3: Attaching a Cable to a DPC

Image g004317.gif

Published: 2011-02-25

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out