Replacing the MX960 Craft Interface
- Disconnecting the Alarm Relay Wires from the MX960 Craft Interface
- Removing the MX960 Craft Interface
- Installing the MX960 Craft Interface
- Connecting the Alarm Relay Wires to the MX960 Craft Interface
Disconnecting the Alarm Relay Wires from the MX960 Craft Interface
To disconnect the alarm relay wires from the router and an alarm-reporting
device (see Figure 1):
- Disconnect the existing wire at the external device.
- Attach an electrostatic discharge (ESD) grounding strap
to your bare wrist, and connect the strap to one of the ESD points
on the chassis.
- Using a 2.5-mm flat-blade screwdriver, loosen
the small screws on the face of the terminal block and remove the
block from the relay contact.
- Using the 2.5-mm flat-blade screwdriver, loosen
the small screws on the side of the terminal block. Remove existing
wires from the slots in the front of the block.
Figure 1: Alarm Relay Contacts
Removing the MX960 Craft Interface
To remove the craft interface (see Figure 2):
- Attach an electrostatic discharge (ESD) grounding strap
to your bare wrist, and connect the strap to one of the ESD points
on the chassis.
- Detach any external devices connected to
the craft interface.
- Loosen the captive screws at the left and right
corners of the craft interface faceplate.
- Grasp the craft interface faceplate and carefully
tilt it toward you until it is horizontal.
- Disconnect the ribbon cable from the back of the
faceplate by gently pressing on both sides of the latch with your
thumb and forefinger. Remove the craft interface from the chassis.
Figure 2: Removing the
Craft Interface
Installing the MX960 Craft Interface
To install the craft interface
(see Figure 3):
- Attach an electrostatic discharge (ESD) grounding strap
to your bare wrist, and connect the strap to one of the ESD points
on the chassis.
- Grasp the craft interface with one hand,
and hold the bottom edge of the craft interface with the other hand
to support its weight.
- Orient the ribbon cable so that it plugs into the
connector socket. The connector is keyed and can be inserted only
one way.
- Align the bottom of the craft interface with the
sheet metal above the card cage and press it into place.
- Tighten the screws on the left and right corners
of the craft interface faceplate.
- Reattach any external devices connected to the
craft interface.
Figure 3: Installing
the Craft Interface
Connecting the Alarm Relay Wires to the MX960 Craft Interface
To connect the alarm relay wires between a router and an alarm-reporting
device (see Figure 4):
- Prepare the required length of replacement wire
with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm2).
- Insert the replacement wires into the slots in
the front of the block. Use a 2.5-mm flat-blade screwdriver to tighten
the screws and secure the wire.
- Attach an electrostatic discharge (ESD) grounding strap
to your bare wrist, and connect the strap to one of the ESD points
on the chassis.
- Plug the terminal block into the relay contact,
and use a 2.5-mm flat-blade screwdriver to tighten the screws on the
face of the block.
- Attach the other end of the wires to the external
device.
Figure 4: Alarm Relay Contacts
Published: 2011-09-08