The Routing Engine is located in the rear slot labeled RE0 on the services gateway. Before you replace the Routing Engine, you must power off the services gateway.
To replace the Routing Engine:
The PWR LED blinks to show you that the services gateway is shutting down. Wait for the services gateway to shut down before proceeding.
Figure 1: Removing a Routing Engine

Figure 2: Installing a Routing Engine

![]() | Note: The Routing Engine may require several minutes to boot. If after this time the OK/FAIL LED is red, remove and reinstall the Routing Engine. If the OK/FAIL LED remains red, the Routing Engine is not functioning properly. Contact your customer support representative. |
To check the status of the Routing Engine:
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
DRAM 1016 MB
Memory utilization 39 percent
CPU utilization:
User 0 percent
Background 0 percent
Kernel 3 percent
Interrupt 0 percent
Idle 97 percent
Model RE-SRX3600
Start time 2008-11-03 10:25:37 PST
Uptime 1 day, 2 hours, 33 minutes, 6 seconds
Last reboot reason 0x1:power cycle/failure
Load averages: 1 minute 5 minute 15 minute
0.02 0.04 0.00
For more information about using the CLI, see the Junos OS manuals.