Table 1 lists the power requirements for various hardware components when the router is operating under typical voltage conditions. For PIC power requirements, see the M10i Multiservice Edge Router PIC Guide.
Table 1: Component Power Requirements
Component | Power Requirement (Watts) @ 48 V | Power Requirement (Amps) @ 48 V |
|---|---|---|
Base system including two HCMs, two power supplies, and one Routing Engine (with fans running at normal speed) | 88.3 | 1.8 A (approximate) |
Routing Engine | 33.6 | 0.7 A |
CFEB/CFEB-E | 67.2 | 1.4 A |
HCM | 10 | 0.2 A |
You can use the information in Table 1 and the M10i Multiservice Edge Router PIC Guide to calculate power consumption for various hardware configurations, input current from a different source voltage, and thermal output, as shown in the following examples. (The examples use a generalized value for PICs of 0.625 A @ 48 V each.)
![]() | Note: We recommend that you provision at least 9.1 A @ 48 VDC and use a facility circuit breaker rated for 15 A minimum. Doing so enables you to operate the router in any configuration without upgrading the power infrastructure, and allows the router to function at full capacity using multiple power supplies. |