Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Download Software
Research a Problem Login required
Case Management Login required
Contract & Product Management Login required
Technical Documentation
Documentation Archive
Enterprise MIBs
File Format Help
Glossary
Portable Libraries
End-of-Life Products
Contact Support
Guidelines and Policies
Security Resources
Home > Support > Technical Documentation > MX Series Routers > MX240 Router Hardware > AC Power Cord Specifications for the MX240 Router
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

MX Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • MX240 Routers
 
 

Related Documentation

  • MX Series
  • MX240 AC Power Supply Description
  • Connecting Power to an AC-Powered MX240 Router
  • Replacing an MX240 AC Power Supply
  • Replacing an MX240 AC Power Supply Cord
  • MX240 AC Power Electrical Safety Guidelines and Warnings
  • MX240 Router AC Power Specifications
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
MX Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
Certification
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Security Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse MX Series Articles  Login required
  • Technical Bulletins for MX Series Login required
  • IOS to Junos Migration Tool Login required
  • ScreenOS to Junos software with enhanced services Migration Tool Login required
Show All Show Fewer 
 
 

AC Power Cord Specifications for the MX240 Router

Each AC power supply has a single AC appliance inlet located on the power supply that requires a dedicated AC power feed. Most sites distribute power through a main conduit that leads to frame-mounted power distribution panels, one of which can be located at the top of the rack that houses the router. An AC power cord connects each power supply to the power distribution panel.

You can order detachable AC power cords, each approximately 8 ft (2.5 m) long that supply AC power to the router. The C19 appliance coupler at the female end of the cord inserts into the AC appliance inlet coupler, type C20 (right angle) as described by International Electrotechnical Commission (IEC) standard 60320. The plug at the male end of the power cord fits into the power source receptacle that is standard for your geographical location.

Table 1 provides specifications and Figure 1 depicts the plug on the AC power cord provided for each country or region.

Table 1: AC Power Cord Specifications

Country

Model Number

Electrical Specification

Plug Type

Australia

CBL-M-PWR-RA-AU

240 VAC, 50 Hz AC

SAA/3/15

China

CBL-M-PWR-RA-CH

220 VAC, 50 Hz AC

CH2-16P

Europe (except Denmark, Italy, Switzerland, and United Kingdom)

CBL-M-PWR-RA-EU

220 or 230 VAC, 50 Hz AC

CEE 7/7

Italy

CBL-M-PWR-RA-IT

230 VAC, 50 Hz AC

CEI 23-16/VII

Japan

CBL-PWR-RA-JP15

125 VAC, 50 or 60 Hz AC

JIS 8303

CBL-M-PWR-RA-JP

220 VAC, 50 or 60 Hz AC

NEMA L6-20P

North America

CBL-PWR-RA-US15

125 VAC, 60 Hz AC

NEMA 5-15P

CBL-PWR-RA-TWLK-US15

125 VAC, 60 Hz AC

NEMA L5-15P

CBL-M-PWR-RA-US

250 VAC, 60 Hz AC

NEMA 6-20

CBL-M-PWR-RA-TWLK-US

250 VAC, 60 Hz AC

NEMA L6-20P

United Kingdom

CBL-M-PWR-RA-UK

240 VAC, 50 Hz AC

BS89/13

Figure 1: AC Plug Types

Image g003187.gif

Warning: The AC power cord for the router is intended for use with the router only and not for any other use.

Image g017253.gif

Warning: Translation from Japanese: The attached power cable is only for this product. Do not use the cable for another product.

Note: In North America, AC power cords must not exceed 4.5 m (approximately 14.75 ft) in length, to comply with National Electrical Code (NEC) Sections 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical Code (CEC) Section 4-010(3). You can order AC power cords that are in compliance.

Warning: The router is pluggable type A equipment installed in a restricted-access location. It has a separate protective earthing terminal (sized for UNC 1/4-20 ground lugs) provided on the chassis in addition to the grounding pin of the power supply cord. This separate protective earthing terminal must be permanently connected to earth.

Caution: Power cords and cables must not block access to device components or drape where people could trip on them.

 

Related Documentation

  • MX Series
  • MX240 AC Power Supply Description
  • Connecting Power to an AC-Powered MX240 Router
  • Replacing an MX240 AC Power Supply
  • Replacing an MX240 AC Power Supply Cord
  • MX240 AC Power Electrical Safety Guidelines and Warnings
  • MX240 Router AC Power Specifications
 

Published: 2011-02-25

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out