Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Download Software
Research a Problem Login required
Case Management Login required
Contract & Product Management Login required
Technical Documentation
Documentation Archive
Enterprise MIBs
File Format Help
Glossary
Portable Libraries
End-of-Life Products
Contact Support
Guidelines and Policies
Security Resources
Home > Support > Technical Documentation > EX Series > AC Power Supply LEDs in an EX8200 Switch
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

EX Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • EX Series
 
 

Related Documentation

  • EX Series
  • AC Power Specifications for EX8200 Switches
  • Power Requirements for EX8208 Switch Components
  • Power Requirements for EX8216 Switch Components
  • AC Power Cord Specifications for an EX8200 Switch
  • Connecting AC Power to an EX8200 Switch
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
EX Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
Enterprise Routing and Switching Certification Track
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Switching Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse EX Series Articles  Login required
  • Technical Bulletins for EX Series Login required
  • IOS to Junos Migration Tool Login required
Show All Show Fewer 
 
 

AC Power Supply LEDs in an EX8200 Switch

An AC power supply has three LEDs on its faceplate. These LEDs display information about the status of the power supply. See Figure 1.

Figure 1: AC Power Supply LEDs on an EX8200 Switch

Image g020511.gif

Table 1 describes the LEDs on an AC power supply in an EX8200 switch.

Table 1: Power Supply LEDs on EX8200 Switches

LED

State

Description

INPUT OK

Unlit

Indicates one of the following:

  • Power supply is disconnected from AC power feed.
  • AC power input voltage is not within normal operating range.
  • No AC power input.

Green

  • AC power input is high-voltage line (200–240 VAC).

Yellow

Note: This LED state applies only to 2000 W AC power supplies.

  • AC power input is low-voltage line (100–120 VAC).

OUTPUT OK

Unlit

Indicates one of the following:

  • DC output voltage is not within normal operating range.
  • Power supply is not supplying DC power correctly.

Green

  • DC power output is within normal operating range.

Yellow

  • Power supply has been disabled internally by the system.

FAIL

Unlit

  • Power supply is functioning normally.

Yellow

  • On steadily—Power supply has failed.
  • Blinking—Demand for output power exceeds the supply.

Note: If the INPUT OK LED and the OUTPUT OK LED are unlit, the AC power cord is not installed properly or the power supply has failed.

If the INPUT OK LED is lit and the OUTPUT OK LED is unlit, the AC power supply is not installed properly or the power supply has an internal failure.

If the FAIL LED is lit, the power supply has failed and must be replaced. If the FAIL LED is blinking, add a power supply to balance the power demand and supply.

 

Related Documentation

  • EX Series
  • AC Power Specifications for EX8200 Switches
  • Power Requirements for EX8208 Switch Components
  • Power Requirements for EX8216 Switch Components
  • AC Power Cord Specifications for an EX8200 Switch
  • Connecting AC Power to an EX8200 Switch
 

Published: 2011-02-14

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out