Skip to content

Support



Juniper was the first North American IP routing vendor to achieve the prestigious TL 9000 certification by the Quality of Excellence for Suppliers of Telecommunications (QuEST) Forum in the router category, for design, development, provision and service and support.



What is J-Care?

It's the world-class service and support that you expect from a company that delivers the industry's best infrastructure and security products. With J-Care, you now have the confidence knowing that Juniper will do our part to keep you on top of the world!


Power Consumption for a DC-Powered JCS1200 Platform

Table 1 lists the power requirements for base DC-powered routers operating under typical voltage conditions and includes nonredundant and redundant power supply configurations.

Table 1: DC-Powered Base JCS1200 Platform Power Requirements

DC Power Supply Configuration

Power Requirement (Watts)

DC Input at 88% Efficiency

Current Requirement (Amps @ –48 VDC)

4 DC power supplies, 4 fan modules, 1 management module, 1 media tray, 1 switch module, 1 midplane, 1 MUX card, 1 alarm panel module, (nonredundant configuration)

735 W

835 W (approximate)

17.4 A (approximate)

4 DC power supplies, 4 fan modules, 1 management module, 1 media tray, 1 switch module, 1 midplane, 1 MUX card, 1 alarm panel module, 12 Routing Engines (nonredundant configuration)

4095 W

4653 W (approximate)

96.9 A (approximate)

4 DC power supplies, 4 fan modules, 2 management modules, 2 media trays, 2 switch modules, 1 midplane, 1 MUX card, 1 alarm panel module, (redundant configuration)

1015 W

1153 W (approximate)

24.0 A (approximate)

4 DC power supplies, 4 fan modules, 2 management modules, 2 media trays, 2 switch modules, 1 midplane, 1 MUX card, 1 alarm panel module, 12 Routing Engines (redundant configuration)

4375 W

4972 W (approximate)

103.6 A (approximate)

Table 2 lists the lists the power requirements for various hardware components when the platform is operating under typical voltage conditions.

Table 2: DC-Powered JCS1200 Platform Component Power Requirements

Item

Power Requirement (Watts)

DC Input at 88% Efficiency

Current Requirement (Amps @ –48 VDC)

Alarm panel module

10 W

11 W (approximate)

0.2 A (approximate)

Fan module

85 W

97 W (approximate)

2.0 A (approximate)

Management module

20 W

23 W (approximate)

0.5 A (approximate)

Media tray

15 W

17 W (approximate)

0.4 A (approximate)

Midplane

10 W

11 W (approximate)

0.2 A (approximate)

MUX card

15 W

17 W (approximate)

0.4 A (approximate)

Power module

36 W

41 W (approximate)

0.9 A (approximate)

Routing Engine

280 W

318 W (approximate)

6.6 A (approximate)

Switch module

45 W

51 W (approximate)

1.1 A (approximate)


Published: 2009-08-06