Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Download Software
Research a Problem Login required
Case Management Login required
Contract & Product Management Login required
Technical Documentation
Documentation Archive
Enterprise MIBs
File Format Help
Glossary
Portable Libraries
End-of-Life Products
Contact Support
Guidelines and Policies
Security Resources
Home > Support > Technical Documentation > EX Series > DC Power Supply in an EX8200 Switch
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

EX Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • EX Series
 
 

Related Documentation

  • EX Series
  • DC Power Specifications for EX8200 Switches
  • DC Power Supply LEDs in an EX8200 Switch
  • Calculating Power Requirements for an EX8216 Switch
  • Installing a DC Power Supply in an EX8200 Switch
  • Removing a DC Power Supply from an EX8200 Switch
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
EX Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
Enterprise Routing and Switching Certification Track
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Switching Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse EX Series Articles  Login required
  • Technical Bulletins for EX Series Login required
  • IOS to Junos Migration Tool Login required
Show All Show Fewer 
 
 

DC Power Supply in an EX8200 Switch

The DC power supplies in EX8200 switches are hot-removable and hot-insertable field-replaceable units (FRUs).

Note: EX8208 switches support 2000 W DC power supplies.

EX8216 switches support 3000 W DC power supplies.

You can install up to six DC power supplies in an EX8200 switch. Power supplies are installed at the bottom of the chassis in slots labeled PSU 0 through PSU 5 (left to right). See Slot Numbering for an EX8208 Switch and Slot Numbering for an EX8216 Switch. All power supplies are accessible from the front of the chassis.

Warning: The switch is pluggable type A equipment installed in a restricted-access location. It has a separate protective earthing terminal provided on the chassis. This separate protective earthing terminal must be permanently connected to earth ground.

Note: EX8216 switches have two protective earthing terminals provided on the chassis, one on the left side of the chassis and the other on the rear of the chassis. Only one of these protective earthing terminals needs to be permanently connected to earth ground. See Chassis Physical Specifications of an EX8216 Switch for the location of the protective earthing terminals.

Note: DC power supplies are shipped only in the redundant configuration of EX8200 switches.

See EX8208 Switch Configurations for details about different EX8208 switch configurations.

See EX8216 Switch Configurations for details about different EX8216 switch configurations.

Each DC power supply weighs approximately 7 lb (3.2 kg) and has two independent pairs of DC input lugs (A: –48V A: RTN and B: – 48V B: RTN ) on the front of the power supply. Each power supply also has an Enable switch, a fan, and four LEDs on the faceplate that indicate the status of the power supply. See Figure 1.

Figure 1: DC Power Supply

Image g020608.gif

Note: A 2000 W DC power supply requires a dedicated 60 A circuit breaker for each input DC feed.

A 3000 W DC power supply requires a dedicated 100 A circuit breaker for each input DC feed.

Each DC power supply connects to the backplane in an EX8208 switch and to the midplane in an EX8216 switch. The backplane in an EX8208 switch and the midplane in an EX8216 switch distribute the output power produced by the power supplies to different switch components. Each DC power supply provides power to all the components in the switch.

The output of each 2000 W DC power supply is 52 VDC. The output power is 2000 W.

The output of each 3000 W DC power supply is 52 VDC. The output power is 3000 W.

A DC power supply works with only one input DC feed connected. It is able to deliver the full output power to all chassis components with only one DC feed connected.

Each DC power supply has its own fan and is cooled by its own internal cooling system. The airflow is from the front of the power supply to the back. Hot air exhausts from the rear of the chassis.

The minimum power configuration required by an EX8200 switch is an N+1 power configuration. In an N+1 power configuration, if one power supply fails or is removed, the remaining power supplies continue to supply power for the system without interruption.

The configuration type of the switch and the input voltage determine the number of power supplies needed (N) for a switch. You must install an additional power supply to meet the required N+1 power redundancy configuration. The DC power supplies each provide independent A and B power feeds, so that dual power feed redundancy is available even in an N+1 configuration. See EX8208 Switch Configurations for details about different EX8208 switch configurations. See EX8216 Switch Configurations for details about different EX8216 switch configurations.

The tables in this section list the N+1 power requirements of different EX8200 switch configurations:

  • Table 1—Lists the N+1 power requirements of EX8208 switch configurations that use 2000 W DC power supplies.
  • Table 2—Lists the N+1 power requirements of EX8216 switch configurations that use 3000 W DC power supplies.

Table 1: N+1 Power Redundancy Configurations for Different EX8208 Switch Configurations Using 2000 W DC Power Supplies

Switch Configuration

Input Voltage

Power Supplies Needed (N)

Power Supplies Needed for N+1

Base

–40 VDC through
–72 VDC

1

2

Fully loaded with 8-port SFP+ line cards

–40 VDC through
–72 VDC

3

4

Table 2: N+1 Power Redundancy Configurations for Different EX8216 Switch Configurations Using 3000 W DC Power Supplies

Switch Configuration

Input Voltage

Power Supplies Needed (N)

Power Supplies Needed for N+1

Base

–40 VDC through
–72 VDC

1

2

Fully loaded with 8-port SFP+ line cards

–40 VDC through
–72 VDC

4

5

 

Related Documentation

  • EX Series
  • DC Power Specifications for EX8200 Switches
  • DC Power Supply LEDs in an EX8200 Switch
  • Calculating Power Requirements for an EX8216 Switch
  • Installing a DC Power Supply in an EX8200 Switch
  • Removing a DC Power Supply from an EX8200 Switch
 

Published: 2011-02-14

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out