Home > Support > Technical Documentation > Clearance Requirements for Airflow and Hardware Maintenance of the SRX3400 Services Gateway
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • SRX3400 Services Gateway Rack Size and Strength Requirements
  • Connecting the SRX3400 Services Gateway to the Building Structure
  • SRX3400 Services Gateway Spacing of Mounting Bracket Holes
 

Clearance Requirements for Airflow and Hardware Maintenance of the SRX3400 Services Gateway

When planning the installation site, you need to allow sufficient clearance around the rack (see Figure 1):

  • For the cooling system to function properly, the airflow around the chassis must be unrestricted. Allow at least 6 in. (15.2 cm) of clearance between services gateways. Allow 5 in. (13 cm) between the side of the chassis and any non-heat-producing surface such as a wall.
  • For service personnel to remove and install hardware components, there must be adequate space at the front and back of the services gateway. At least 24 in. (61 cm) is required both in front of and behind the services gateway. NEBS GR-63 recommends that you allow at least 30 in. (76 cm) in front of the rack and 24 in. (61 cm) behind the rack.

Figure 1: Clearance Requirements

Clearance Requirements
 

Related Documentation

  • SRX3400 Services Gateway Rack Size and Strength Requirements
  • Connecting the SRX3400 Services Gateway to the Building Structure
  • SRX3400 Services Gateway Spacing of Mounting Bracket Holes
 

Published: 2011-11-11

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out