Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Download Software
Research a Problem Login required
Case Management Login required
Contract & Product Management Login required
Technical Documentation
Documentation Archive
Enterprise MIBs
File Format Help
Glossary
Portable Libraries
End-of-Life Products
Contact Support
Guidelines and Policies
Security Resources
Home > Support > Technical Documentation > EX Series > EX8216 Hardware Documentation > Clearance Requirements for Airflow and Hardware Maintenance for an EX8216 Switch
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...

EX Series Search

Advanced Search |  Search Tips
 

Supported Platforms

  • EX8216
 
 

Related Documentation

  • EX Series
  • Cooling System and Airflow in an EX8216 Switch
  • Cabinet Requirements and Specifications for an EX8216 Switch
  • Rack Requirements for an EX8216 Switch
  • Rack-Mounting and Cabinet-Mounting Warnings
 
Recent Community Posts
Show All Show Fewer 
 
 
Related Links
EX Series Product Literature
  • Junos Central
  • Junos Technotes
  • Junos Day One Books
Enterprise Routing and Switching Certification Track
  • Fast Track Certification Program
  • Certification Study Guides
Junos Technical Education Courses (Free)
  • Networking Fundamentals
  • Junos As A Second Language
  • Junos As A Scripting Language
  • Junos As A Switching Language
  • Juniper Networks Books
Support
  • Junos Software (Canada & US)  Login required
  • Junos Software (Worldwide) Login required
  • Knowledge Base - Browse EX Series Articles  Login required
  • Technical Bulletins for EX Series Login required
  • IOS to Junos Migration Tool Login required
Show All Show Fewer 
 
 

Clearance Requirements for Airflow and Hardware Maintenance for an EX8216 Switch

When planning the site for installing an EX8216 switch, you must allow sufficient clearance around the switch.

Note: To manage airflow in a hot-aisle--cold-aisle data center setup, you might want to use the customized rack solution for EX8200 switches offered by Chatsworth Products, Inc.

Follow these clearance requirements:

  • Allow at least 6 in. (15.2 cm) of clearance on each side of the chassis. For the cooling system to function properly, the airflow around the chassis must be unrestricted. See Figure 1 and Figure 2.

    Note: Do not block the air intake below the power supply slots.

    Figure 1: Airflow Through the EX8216 Switch Chassis

    Image g020607.gif

    Figure 2: Airflow for the EX8216 Switch Chassis Rear

    Image g020640.gif
  • If you are mounting the switch on a rack or cabinet along with other equipment, ensure that the exhaust from other equipment does not blow into the intake vents of the chassis.
  • Leave at least 24 in. (61 cm) both in front of and behind the switch. Allow at least 6 in. (15.2 cm) of clearance on each side of the chassis. Leave adequate space at the front of the switch for service personnel to remove and install hardware components. NEBS GR-63 recommends that you allow at least 30 in. (76.2 cm) in front of the rack or cabinet and 24 in. (61 cm) behind the rack or cabinet. See Figure 3.

    Figure 3: Clearance Requirements for Airflow and Hardware Maintenance for an EX8216 Switch Chassis

    Image g020606.gif
 

Related Documentation

  • EX Series
  • Cooling System and Airflow in an EX8216 Switch
  • Cabinet Requirements and Specifications for an EX8216 Switch
  • Rack Requirements for an EX8216 Switch
  • Rack-Mounting and Cabinet-Mounting Warnings
 

Published: 2011-02-14

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out