Home > Support > Technical Documentation > SRX3600 Services Gateway Cabinet Size and Clearance Requirements
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • SRX3600 Services Gateway Cabinet Airflow Requirements
  • SRX3600 Services Gateway Rack Size and Strength Requirements
  • SRX3600 Services Gateway Spacing of Mounting Bracket Holes
  • Clearance Requirements for Airflow and Hardware Maintenance of the SRX3600 Services Gateway
  • SRX3600 Services Gateway NEBS and ETSI Compliance
 

SRX3600 Services Gateway Cabinet Size and Clearance Requirements

The minimum size cabinet that can accommodate the services gateway is 27.5 in. (69.8 cm) wide and 31.5 in. (80.0 cm) deep. The cabinet must allow at least 5 in. (13 cm) of clearance on each side of the chassis to allow for cooling air to flow through the vents on each side of the device. A cabinet larger than the minimum requirement provides better airflow and reduces the chance of overheating.

Allow at least 3 in. (7.6 cm) of vertical clearance between the top and bottom of the services gateway and other devices in the cabinet.

The minimum front and rear clearance requirements depend on the mounting configuration you choose. The minimum total clearance inside the cabinet is 30.7 in. (78 cm) between the inside of the front door and the inside of the rear door.

The device has not been tested for NEBS and ETSI compliance when mounted inside an enclosed cabinet. NEBS certification only applies if the device is mounted in a two-post or four-post rack.

 

Related Documentation

  • SRX3600 Services Gateway Cabinet Airflow Requirements
  • SRX3600 Services Gateway Rack Size and Strength Requirements
  • SRX3600 Services Gateway Spacing of Mounting Bracket Holes
  • Clearance Requirements for Airflow and Hardware Maintenance of the SRX3600 Services Gateway
  • SRX3600 Services Gateway NEBS and ETSI Compliance
 

Published: 2011-09-21

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out