Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Download Software
Research a Problem Login required
Case Management Login required
Contract & Product Management Login required
Technical Documentation
Documentation Archive
Enterprise MIBs
File Format Help
Glossary
Portable Libraries
End-of-Life Products
Contact Support
Guidelines and Policies
Security Resources
Home > Support > Technical Documentation > EX Series > EX3200 Hardware Documentation > Uplink Modules in EX3200 Switches
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • EX Series
  • Network Port LEDs in EX3200 Switches
  • Uplink Modules Connector Pinout Information for EX3200 Switches
  • Optical Interface Support in EX3200 Switches
  • SFP+ Direct Attach Cables for EX Series Switches
  • Installing an Uplink Module in an EX3200 Switch
  • Troubleshooting Uplink Module Installation or Replacement on EX3200 Switches
 

Uplink Modules in EX3200 Switches

EX3200 switches support three types of uplink modules:

  • SFP uplink module—Provides four ports for 1-gigabit small form-factor pluggable (SFP) transceivers.

    Note: On an EX3200 switch, if you install a transceiver in an SFP uplink module, all the network ports from the last four built-in ports are disabled and remain disabled until you reboot the switch. After rebooting the switch, only the corresponding network port from the last four built-in ports remains disabled, the rest of the network ports are enabled.
    The disabled port is not listed in the output of the show interface command.
    For example, if you install an SFP transceiver in port 2 on the uplink module (ge-0/1/2) on 24-port models, then ge-0/0/22 is disabled after you reboot the switch.

    On an EX3200 switch, if you replace a transceiver multiple times in quick succession in a port that uses fiber-optic connectors, the switch might not create an interface for that port and that port might be disabled.
    The disabled port is not listed in the output of the show interface command.
    For example, if you replace an SFP transceiver in port 2 on the uplink module (ge-0/1/2) multiple times in quick succession, then ge-0/1/2 might be disabled.

  • SFP+ uplink module—Provides two ports for 10-gigabit small form-factor pluggable (SFP+) transceivers when configured to operate in 10-gigabit mode or four ports for 1-gigabit small form-factor pluggable (SFP) transceivers when configured to operate in 1-gigabit mode.

    Note: On an EX3200 switch, if you install a transceiver in an SFP+ uplink module when the uplink module is operating in the 1-gigabit mode, all the network ports from the last four built-in ports are disabled and remain disabled until you reboot the switch. After rebooting the switch, only the corresponding network port from the last four built-in ports remains disabled, the rest of the network ports are enabled.
    The disabled port is not listed in the output of the show interface command.
    For example, if you install an SFP transceiver in port 2 on the uplink module (ge-0/1/2), then ge-0/0/22 is disabled after rebooting the switch.

  • XFP uplink module—Provides two ports for 10-gigabit small form-factor pluggable (XFP) transceivers.

Note: When a new uplink module is installed in the switch or an existing uplink module is replaced with another uplink module, the switch detects the newly installed uplink module. The switch creates the required interfaces if the uplink module has transceivers in its ports and when new transceivers are installed in those ports.

When connecting uplink module ports, you can install an SFP uplink module at one end of the connection and install an SFP+ uplink module configured to operate in the 1-gigabit mode at the other end. Likewise, you can install an XFP uplink module at one end of the connection and install an SFP+ uplink module configured to operate in the 10-gigabit mode at the other end.

This topic describes:

  • SFP Uplink Module
  • SFP+ Uplink Module
  • XFP Uplink Module

SFP Uplink Module

Figure 1 shows the SFP uplink module, which provides four ports for 1-gigabit SFP transceivers.

Figure 1: SFP Uplink Module

SFP Uplink
Module

SFP uplink modules are shipped with dust covers preinstalled in the ports.

The SFP uplink module requires Junos OS for EX Series switches, Release 9.0 or later.

SFP+ Uplink Module

SFP+ uplink modules can be used for either SFP+ or SFP transceivers. You configure the operating mode on the module to match the type of transceiver you want to use—for SFP+ transceivers, you configure the 10-gigabit operating mode, and for SFP transceivers, you configure the 1-gigabit operating mode. See Setting the Mode on an SFP+ Uplink Module (CLI Procedure).

By default, the SFP+ uplink module operates in the 10-gigabit mode and supports only SFP+ transceivers. If you have not changed the module from the default setting and you want to use SFP+ transceivers, you do not need to configure the operating mode.

If the operating mode and the configured mode for an SFP+ uplink module are different, it is shown in the output of show chassis pic fpc-slot slot number pic-slot 1.

Figure 2 shows the SFP+ uplink module.

Figure 2: SFP+ Uplink Module

SFP+
Uplink Module

Transceivers are supported in the uplink module’s ports as follows:

  • SFP+ transceivers are supported in ports 0 and 2.
  • SFP transceivers are supported in all four ports.

The ports that support SFP+ transceivers are labeled 10 G on the uplink module’s faceplate (see Figure 2).

Note: When an SFP+ uplink module is operating in 10-gigabit mode:

  • Only the 10-gigabit ports (ports 0 and 2) are enabled.
  • You can use only SFP+ transceivers in those ports.

When an SFP+ uplink module is operating in 1-gigabit mode:

  • All four ports are enabled.
  • You can use only SFP transceivers in all four ports.

The SFP+ uplink module has an LED on the faceplate (labeled Operating mode LED in Figure 2) that indicates the operating mode. If the uplink module is operating in the 10-gigabit mode, the LED is lit. If the uplink module is operating in the 1-gigabit mode, the LED is unlit.

SFP+ uplink modules are shipped with dust covers preinstalled in the ports.

The SFP+ uplink module requires Junos OS for EX Series switches, Release 9.4 or later.

XFP Uplink Module

Figure 3 shows the XFP uplink module, which provides two ports for 10-gigabit XFP transceivers.

Figure 3: XFP Uplink Module

XFP Uplink
Module

XFP uplink modules are shipped with a dust cover preinstalled in one port.

The XFP uplink module requires Junos OS for EX Series switches, Release 9.0 or later.

 

Related Documentation

  • EX Series
  • Network Port LEDs in EX3200 Switches
  • Uplink Modules Connector Pinout Information for EX3200 Switches
  • Optical Interface Support in EX3200 Switches
  • SFP+ Direct Attach Cables for EX Series Switches
  • Installing an Uplink Module in an EX3200 Switch
  • Troubleshooting Uplink Module Installation or Replacement on EX3200 Switches
 

Published: 2011-12-06

 
  • About Juniper
  • The New Network
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out