Rate and give feedback:
Feedback Received. Thank You!
SONET/SDH OC12/STM4 (Multi-Rate) PICs with SFP (T640 Router)
Figure 1: 1-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC | Figure 2: 4-Port SONET/SDH OC12/STM4 (Multi-Rate) PIC |
Software release | - 1-port: Junos OS Release 8.4 and later (Type 1)
- 4-port: Junos OS Release 8.3 and later (Type 2)
For information on which FPCs support these PICs, see T640 PIC/FPC Compatibility . |
Description | - 1-port: Rate-selectable using one of the following rates:
- 1-port OC3/STM1
- 1-port OC12/STM4
- 1-port OC12c/STM4c
- 4-port: Rate-selectable using one of the following rates:
- 1-port OC12/STM4
- 1-port OC48/STM16
- 1-port OC48c/STM16c
- 4-port OC3c/STM1c
- 4-port OC12c/STM4c
- Power requirement:
- 1-port: 0.20 A @ 48 V (9.5 W)
- 4-port: 0.40 A @ 48 V (19 W)
|
Hardware features | - Multiplexing and demultiplexing
- Rate policing on input
- Rate shaping on output
- Packet buffering, Layer 2 parsing
|
Software features | - Optical diagnostics and related alarms
- Per-port SONET/SDH framing
- Link aggregation
- Alarm and event counting and detection
- Dual-router automatic protection switching (APS)
- Multiprotocol Label Switching (MPLS) fast reroute
- Encapsulations:
- Circuit cross-connect (CCC)
- Translational cross-connect (TCC)
- Frame Relay
- High-Level Data Link Control (HDLC)
- Point-to-Point Protocol (PPP)
|
Cables and connectors | You can install any transceiver supported
by the PIC. Note:
To extend the life of the laser, when a PIC is not being
actively used with any valid links, take the PIC offline until you
are ready to establish a link to another device. For information about
taking a PIC offline, see the request chassis pic offline command in the Junos OS System Basics and Services Command Reference. |
LEDs | One tricolor per port: - Off—Not enabled
- Green—Online with no alarms or failures
- Yellow—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events | - SONET alarms:
- Alarm indication signal—line (AIS-L)
- Alarm indication signal—path (AIS-P)
- Bit error rate—signal degrade (BERR-SD)
- Bit error rate—signal fail (BERR-SF)
- Bit interleaved parity (BIP) error B1, B2, B3
- Far-end bit error: remote error indication—line
(REI-L), far-end line coding violations (CV-LFE)
- Far-end bit error: remote error indication—path
(REI-P), far-end path coding violations (CV-PFE)
- Loss of frame (LOF)
- Loss of pointer (LOP-P)
- Loss of signal (LOS)
- Payload label mismatch (PLM-P)
- Payload unequipped (unequipped STS at path level) (UNEQ-P)
- Remote defect indication—line (RDI-L)
- Remote defect indication—path (RDI-P)
- SDH alarms:
- Administrative unit alarm indication signal (AU-AIS)
- Bit error rate signal degrade (BERR-SD)
- Bit error rate signal fail (BERR-SF)
- Bit interleaved parity (BIP) error B1, B2, B3
- Higher order path—payload label mismatch (HP-PLM)
- Higher order path—loss of pointer (HP-LOP)
- Higher order path—remote defect indication (HP-RDI)
- Higher order path—unequipped (HP-UNEQ)
- Loss of frame (LOF)
- Loss of signal (LOS)
- Multiplex section—alarm indication signal (MS-AIS)
- Multiplex section—remote defect indication (MS-RDI)
- Multiplex section—remote error indication (MS-REI)
Error detection: - Errored seconds (ES-S, ES-L, ES-P)
- Far-end errored seconds (ES-LFE, ES-PFE)
- Far-end severely errored seconds (SES-LFE, SES-PFE)
- Far-end unavailable seconds (UAS-LFE, UAS-PFE)
- Severely errored framing (SEF)
- Severely errored framing seconds (SEFS-S)
- Severely errored seconds (SES-S, SES-L, SES-P)
- Unavailable seconds (UAS-L, UAS-P)
|
Published: 2011-03-11
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.