Rate and give feedback:
Feedback Received. Thank You!
Adaptive Services II FIPS EOL PIC (M7i Router)
Software release | - Junos OS Release 7.2 and later
|
Description | - Junos-FIPS requires an Adaptive Services II FIPS PIC for
external IPSec connections. See the Secure Configuration Guide for Common Criteria and Junos-FIPS for more
information.
- Supports tunnel services. This feature is included with
the PIC and does not require an individual license.
- Individual licenses must be purchased for additional services
such as Network Address Translation (NAT), stateful firewall, intrusion
detection services (IDS), IPSec. J-Flow accounting, and voice services.
For information about which services are supported by PIC and platform
type, see the Junos OS Services Interfaces Configuration Guide
. - Power requirement: 0.4 A @ 48 V (19 W)
|
Hardware features | - Support for up to 2000 service sets
- Active monitoring on up to 1 million flows
- Support for MTUs up to 9192 bytes for Gigabit Ethernet
and SONET interfaces
|
Software features | For a list of the software features available
for services PICs, see the Junos OS Services Interfaces Configuration Guide . Depending on your Junos OS Release and individual licenses,
software features for this PIC can include: - Stateful firewall with packet inspection:
- Detects SYN attacks, ICMP and UDP floods, and ping-of-death
attacks
- NAT for IP addresses
- Port Address Translation (PAT) for port numbers
- J-Flow accounting exports cflowd version 5 and version
8 records
- Tunnel services:
- IP-IP unicast tunneling
- GRE unicast tunneling—Supports GRE fragmentation
- PIM sparse mode unicast tunneling
- Virtual tunnel interface for Layer 3 VPNs
- IPSec encryption
- Voice services:
- Compressed Real-Time Protocol (CRTP)
- Encapsulations:
- Multilink Frame Relay (MLFR)
- Multilink Point-to-Point Protocol (MLPP)
|
LEDs | Status LED, one tricolor: - Off—PIC is offline and it is safe to remove it from
the chassis.
- Green—PIC is operating normally.
- Yellow—PIC is initializing.
- Red—PIC has an error or failure and no further harm
can be done by removing it from the chassis.
Application LED, one tricolor: - Off—Service is not running.
- Green—Service is running under acceptable load.
- Yellow—Service is overloaded.
|
Published: 2012-03-21
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.