Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All
     

    Related Documentation

     

    SONET/SDH OC48/STM16 (Multi-Rate) PIC with SFP (M120 Router)

    Software release

    Description

    • Rate-selectable using one of the following rates:
      • 1-port OC3c
      • 1-port OC12
      • 1-port OC12c
      • 1-port OC48
      • 1-port OC48c
    • Power requirement: 0.20 A @ 48 V (9.5 W)

    Hardware features

    • Multiplexing and demultiplexing
    • Rate policing on input
    • Rate shaping on output
    • Packet buffering, Layer 2 parsing

    Software features

    • Optical diagnostics and related alarms
    • Per-port SONET/SDH framing
    • Link aggregation
    • Alarm and event counting and detection
    • Dual-router automatic protection switching (APS)
    • Multiprotocol Label Switching (MPLS) fast reroute
    • Encapsulations:
      • High-Level Data Link Control (HDLC)
      • Frame Relay
      • Circuit cross-connect (CCC)
      • Translational cross-connect (TCC)
      • Point-to-Point Protocol (PPP)

    Cables and connectors

    You can install any transceiver supported by the PIC.

    • Duplex LC/PC connector (Rx and Tx)
    • SONET/SDH OC3/STM1 small form-factor pluggable (SFP) transceivers:
      • Multimode (model number: SFP-OC3-SR)
      • Intermediate reach (IR-1) (model number: SFP-OC3-IR)
      • Long reach (LR-1) (model number: SFP-OC3-LR)

      Optical interface specifications—see SONET/SDH OC3/STM1 Optical Interface Specifications

    • SONET/SDH OC12/STM4 small form-factor pluggable (SFP) transceivers:
      • Short reach (SR-1)
      • Intermediate reach (IR-1)
      • Long reach (LR-1)

      Optical interface specifications—see SONET/SDH OC12/STM4 Optical Interface Specifications

    • SONET/SDH OC48/STM16 small form-factor pluggable (SFP) transceivers:
      • Short reach (SR-1) (model number: SFP-1OC48-SR)
      • Intermediate reach (IR-1) (model number: SFP-1OC48-IR)
      • Long reach (LR-1) (model number: SFP-1OC48-LR)

      Optical interface specifications—see SONET/SDH OC48/STM16 Optical Interface Specifications

    Note: To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the CLI Explorer.

    LEDs

    One tricolor per port:

    • Off—Not enabled
    • Green—Online with no alarms or failures
    • Yellow—Online with alarms for remote failures
    • Red—Active with a local alarm; router has detected a failure

    Alarms, errors, and events

    • SONET alarms:
      • Alarm indication signal—line (AIS-L)
      • Alarm indication signal—path (AIS-P)
      • Bit error rate signal degrade (BERR-SD)
      • Bit error rate signal fail (BERR-SF)
      • Bit interleaved parity (BIP) error B1
      • Bit interleaved parity (BIP) error B2
      • Bit interleaved parity (BIP) error B3
      • Loss of frame (LOF)
      • Loss of pointer (LOP-P)
      • Loss of signal (LOS)
      • Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
      • Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
      • Payload mismatch (path label mismatch) (PLM-P)
      • Payload unequipped (unequipped STS at path level) (UNEQ-P)
      • Remote defect indication—line (RDI-L)
      • Remote defect indication—path (RDI-P)
    • SDH alarms:
      • Multiplex section alarm indication signal (MS-AIS)
      • Administrative unit alarm indication signal (AU-AIS)
      • Bit error rate signal degrade (BERR-SD)
      • Bit error rate signal fail (BERR-SF)
      • Bit interleaved parity (BIP) error B1
      • Bit interleaved parity (BIP) error B2
      • Bit interleaved parity (BIP) error B3
      • Loss of frame (LOF)
      • Loss of pointer (HP-LOP)
      • Loss of signal (LOS)
      • Multiplex section remote error indication (MS-REI)
      • Higher path label mismatch (HP-PLM)
      • Higher path unequipped (HP-UNEQ)
      • Multiplex section remote defect indication (MS-RDI)
      • Higher path remote defect indication (HP-RDI)
    • Errored seconds (ES-S, ES-L, ES-P), far-end errored seconds (ES-LFE, ES-PFE), far-end severely errored seconds (SES-LFE, SES-PFE), far-end unavailable seconds (UAS-LFE, UAS-PFE)
    • Severely errored framing (SEF), severely errored framing seconds (SEFS-S), severely errored seconds (SES-S, SES-L, SES-P), unavailable seconds (UAS-L, UAS-P)
     

    Related Documentation

     

    Modified: 2014-10-08