Juniper Networks EX Series Ethernet Switches provide scalable connectivity for the enterprise market, including branch offices, campus locations, and data centers. The switches run the Juniper Networks Junos operating system (Junos OS), which provides Layer 2 and Layer 3 switching, routing, and security services. The same Junos OS code base that runs on EX Series switches also runs on all Juniper Networks J Series, M Series, MX Series, and T Series routers and SRX Series services gateways.
Juniper Networks EX2200 Ethernet Switches provide connectivity for low-density environments.
This topic describes:
EX2200 switches are available in models with 12 , 24, or 48 built-in network ports. The compact, fanless model, EX2200-C switches have 12 network ports.
EX2200 switches provide:
Each EX2200 switch except the EX2200-C switch model has four uplink ports that support 1-gigabit small form-factor pluggable (SFP) transceivers for use with fiber connections and copper connections.
Each EX2200-C switch has two dual-purpose uplink ports. Each dual uplink port consists of an RJ-45 port (in which you can connect a copper Ethernet cable) and an SFP port (into which you can plug a transceiver). Only one of the ports can be active at a time. By default, if you connect a copper Ethernet cable to the RJ-45 port, this port becomes the active port provided that there is no connection made on the other port. If you plug a transceiver into the SFP port, this port becomes the active port whether or not a copper Ethernet cable is connected to the other port. You can change this default behavior by explicitly configuring a media type--copper or fiber---for the dual-purpose port using the media-type command. For more information, see Configuring the Media Type on Dual-Purpose Uplink Ports (CLI Procedure)
For information about the supported optical and copper interfaces, see Optical Interface Support in EX2200 Switches.
Each EX2200 switch except the EX2200-C switch model has an RJ-45 console port that accepts a cable with RJ-45 connector.
The EX2200-C switch has two console ports: an RJ-45 port and a Mini-USB Type-B port. The RJ-45 console port accepts a cable with an RJ-45 connector and the Mini-USB Type-B console port accepts a Mini-B plug (5-pin) connector to connect to the console management device. The switch activates only one console port at a time, either the RJ-45 console port or the Mini USB type-B console port. By default, the RJ-45 port is the active console port and the Mini-USB Type-B port is the passive console port. You can change the default setting of a console port using the port-type command. See Configuring the Console Port Type (CLI Procedure).
On an EX2200-C switch model you can install a cable guard to secure the cables connected to the switch. The cable guard has slots in the front of it through which you can pass all the cables to prevent them from being accidently unplugged or removed after they are connected. See Mounting an EX2200 Switch on a Desk or Other Level Surface.
Each EX2200-C switch model has security slots on the left and right panels of the chassis. The security slots allow you to lock and secure the chassis in the installation site using a standard cable lock . See Mounting an EX2200 Switch on a Desk or Other Level Surface.
EX2200 switches are available in models with or without PoE/PoE+ capability. Models that support PoE/PoE+ provide that support on all network ports. PoE ports provide electrical current to devices—such as IP phones, wireless access points, and security cameras—through network cables, thus eliminating the need for separate power cords for those devices.
EX2200 switches with DC power supply do not provide PoE.
EX2200 switches running Junos OS Release 10.3 or later support powered devices that comply with IEEE 802.3af (PoE) and IEEE 802.3at (PoE+).
![]() | Note: IEEE 802.3at class 4 powered devices require category 5 or higher Ethernet cables. |
EX2200 switches running Junos OS Release 10.2 or earlier support powered devices that comply with IEEE 802.3af (PoE).
The remainder of this topic uses the term PoE to refer to both PoE and PoE+ unless there is a need to distinguish between the two.
The front panel of an EX2200 switch except the EX2200-C switch models consists of the following components:
Figure 1 shows the front panel of an EX2200 switch with 48 Gigabit Ethernet ports. Figure 2 shows the front panel of an EX2200 switch with 24 Gigabit Ethernet ports.
Figure 1: Front Panel of an EX2200 Switch with 48 Gigabit Ethernet Ports

Figure 2: Front Panel of an EX2200 Switch with 24 Gigabit Ethernet Ports

The front panel of an EX2200-C switch consists of the following components:
Figure 3 shows the front panel of an EX2200-C Switch with 12 Gigabit Ethernet PoE+ ports and Figure 4 shows the front panel of an EX2200-C Switch with 12 Gigabit Ethernet non-PoE ports.
Figure 3: Front Panel of an EX2200-C Switch with 12 Gigabit Ethernet Ports (PoE+)

Figure 4: Front Panel of an EX2200-C Switch with 12 Gigabit Ethernet Ports (non-PoE)

The rear panel of the EX2200 switch except the EX2200-C switch models consists of the following components:
Figure 5 shows the rear panel of an EX2200 switch with an AC power supply.
All EX2200 switches except the EX2200-C switch model have three exhaust openings on the rear panel. The two exhaust openings on the left have fans behind them and are open. The exhaust opening on the right is open on Power over Ethernet (PoE) models and closed on non-PoE models. On PoE models, this opening exhausts the air from the fan at the air intake for the power supply on the side panel.
The power cord retainer clips extend out of the chassis by 3 in.
Figure 5: Rear Panel of an EX2200 Switch With an AC Power Supply

The rear panel of an EX2200-C switch consists of the following components:
Figure 6 shows the rear panel of an EX2200-C-12P switch with heatsink.
EX2200-C switches being fanless models have no exhaust openings. The switch has vents on the top and on both the sides of the chassis. The PoE+ models have heatsink installed in the rear panel to dissipate the heat, while non-PoE models have no heatsink.
Figure 6: Rear Panel of an EX2200-C-12P Switch with Heatsink