Remote IMV Rule
|
Configures integrity measurement software that a client
must run to verify a particular aspect of the client’s integrity,
such as the client’s operating system, patch level, or virus
protection.
|
- Enter the rule name.
- Select the IMV option.
- Click OK.
|
NHC Rule
|
(Windows only)—Specifies the location of a custom
DLL. Host Checker calls the DLL to perform customized client-side
checks. If the DLL returns a success value to Host Checker, then the
Infranet Controller considers the rule met.
|
- Enter the rule name, vendor name and the path
to NHC DLL on client machines.
- Select the Monitor this rule for
change in result check box to continuously monitor the policy
compliance of endpoints.
- Click OK.
|
Ports Rule
|
Controls the network connections that a client can generate
during a session. This rule type ensures that certain ports are open
or closed on the client machine before the user can access the Infranet
Controller.
|
- Enter the rule name.
- Select the Required option
to specify that these ports are open or closed.
- Enter a comma delimited port list (without spaces)
of ports or port ranges, such as: 1234,11000-11999,1235.
- Click OK.
|
Process Rule
|
Controls the software that a client may run during a
session. This rule type ensures that certain processes are running
or not running on the client machine before the user can access resources
protected by the Infranet Controller.
|
- Enter the rule name.
- Select the Required option
to specify that these ports are open or closed.
- Enter the process name (executable file), such
as: good-app.exe.
- Enter the MD5 checksums value of each executable
file to which you want the policy to apply (optional).
- Select the Monitor this rule for
change in result check box to continuously monitor the policy
compliance of endpoints.
- Click OK.
|
File Rule
|
Ensures that certain files are present or not present
on the client machine before the user can access the Infranet Controller.
You may also use file checks to evaluate the age and content (through
MD5 checksums) of required files and allow or deny access accordingly.
|
- Enter the rule name.
- Enter the file name such as: c:\temp\bad-file.txt
or /temp/bad-file.txt.
- Select the Required option
to specify that these ports are open or closed.
- Enter the minimum version of the file (optional).
For example, if you require notepad.exe to be present on the client,
you can enter 5.0 in the box. Host Checker accepts
version 5.0 and later of notepad.exe.
- Enter the maximum age of files in the File modified
less than (days ago) box.
- Enter the MD5 checksums value of each executable
file to which you want the policy to apply (optional).
- Select the Monitor this rule for
change in result check box to continuously monitor the policy
compliance of endpoints.
- Click OK.
|
Registry Setting Rule
|
(Windows only)—Controls the corporate PC images,
system configurations, and software settings that a client must have
to access the Infranet Controller. This rule type ensures that certain
registry keys are set on the client machine before the user can access
the Infranet Controller. You may also use registry checks to evaluate
the age of required files and allow or deny access accordingly.
|
- Enter the rule name.
- Select Registry root key from
the drop-down list.
- Enter the path to the application folder for the
registry subkey.
- Enter the name of the key’s value
- Select the key value’s type (String, Binary, or DWORD) from the drop-down
list (optional).
- Enter the registry value.
- Select the Set Registry value
specified in the criteria check box.
- Select Minimum Version to
allow the specified version or newer versions of the application.
For example, you can use this option to specify version information
for an antivirus application to make sure that the client antivirus
software is current. The Infranet Controller uses lexical sorting
to determine if the client contains the specified version or later.
- Select the Monitor this rule for
change in result check box to continuously monitor the policy
compliance of endpoints.
- Click OK.
|
NetBIOS Rule
|
(Windows only, does not include Windows Mobile)—Checks
the NetBIOS name of the client machine before the user can access
the Infranet Controller.
|
- Enter the rule name.
- Select the Required option
to require that NetBIOS name of the client machine matches or does
not match any one of the names you specify.
- Enter a comma-delimited list (without spaces) of
NetBIOS names. The name can be up to 15 characters in length. You
can use wildcard characters in the name and it is not case-sensitive.
For example:
md*, m*xp and *xp all match MDXP.
- Click OK.
|
MAC Address Rule
|
(Windows only)—Checks the MAC addresses of the
client machine before the user can access the Infranet Controller.
|
- Enter the rule name.
- Select the Required option
to require that a MAC address of the client machine matches or does
not match any of the addresses you specify.
- Enter a comma-delimited list (without spaces) of
MAC addresses in the form XX:XX:XX:XX:XX:XX where the X’s are
hexadecimal numbers. For example:
00:0e:1b:04:40:29.
- Click OK.
|
Machine Certificate Rule
|
(Windows only)— Checks that the client machine
is permitted access by validating the machine certificate stored on
the client machine.
|
- Enter the rule name.
- From the Select Issuer Certificate list, select
the certificate that you want to retrieve from the user’s machine
and validate. Or, select Any Certificate to skip
the issuer check and only validate the machine certificate based on
the optional criteria that you specify below.
- Enter Certificate field and Expected
value to specify any additional criteria that Host Checker should
use when verifying the machine certificate.
- Click OK.
|