To display statistics for channelized SONET and
SDH interfaces, use the show controllers sonet command. The following section describes
some of the options for the command and shows some sample displays.
From User Exec mode, use the following show commands to monitor and display the T3, T1/E1,
and HDLC serial data channel information:
Display E1 or T1 statistics for E1 or T1 over a VT.
host1#show controllers sonet 2/0 e1
Display T3 statistics.
host1#show controllers sonet 2/1 ds3
Display statistics for the section, line, path, and tributary
layers.
host1#show controllers sonet 2/1 section
Display the configuration for channelized SONET and SDH
interfaces.
host1#show controllers sonet 2/0 configuration
Display statistics for serial interfaces.
host1#show interfaces serial 2/0:1/1/1/1/1
Setting a Baseline
You can set statistics baselines for serial interfaces,
subinterfaces, and circuits using the baseline interface
serial command. You can also set statistics baselines
for the section, line, and path layers using the baseline
interface sonet command. Use the delta options with
the show commands to display statistics
with the baseline subtracted.
Output Filtering
You can use the output filtering feature of the show command to include or exclude lines of output
based on a text string you specify. See Command Line Interface in JUNOSe System Basics Configuration Guide, for details.
baseline interface serial
Use to set a statistics baseline for serial interfaces.
The router implements the baseline by reading and storing
the statistics at the time the baseline is set and then subtracting
this baseline whenever baseline-relative statistics are retrieved.
Use the delta keyword with the show interfaces
serial command to view the baseline statistics.
Use to set a statistics baseline for the SONET/SDH line
layer.
The router implements the baseline by reading and storing
the MIB statistics at the time the baseline is set and then subtracting
this baseline whenever baseline-relative statistics are retrieved.
Use the total [ delta ] keywords with the show controllers
sonet line command to view the baseline statistics.
Use to set a statistics baseline for the SONET/SDH path
layer.
The router implements the baseline by reading and storing
the MIB statistics at the time the baseline is set and then subtracting
this baseline whenever baseline-relative statistics are retrieved.
Use the total [ delta ] keywords with the show controllers
sonet path command to view the baseline statistics.
Use to set a statistics baseline for the SONET/SDH section
layer.
The router implements the baseline by reading and storing
the MIB statistics at the time the baseline is set and then subtracting
this baseline whenever baseline-relative statistics are retrieved.
Use the total [ delta ] keywords with the show controllers
sonet section command to view the baseline statistics.
Use to display the configuration for channelized SONET
and SDH interfaces.
Specify an interface in slot/port format.
To view information for a controller and all layers above
that controller, specify a controller. For example, to view all controllers
on interface 3/0, use show controllers sonet 3/0
configuration. To view information for path 1 only,
use show controllers sonet 3/0:1 configuration.
Field descriptions
Interface specifier in slot/port format
channelized—Number of channels and speed for the
interface
ifAdminStatus—Configured status of the interface:
up or down
description—Configured description of the controller
snmp trap link-status—State of SNMP link status
processing for the section and line layers of the interface: enabled
or disabled
alarms used for operational status calculation—Types
of defects that the router uses to determine the operational status
of the interface at the section and line layers
defect trigger soaking delay—Time that the router
waits to set an alarm when the router records a defect at the section
or line layer
Operational Status—Physical state of the interface:
up—Interface is operational
down, failure alarm—Interface is not operational;
type of defect that caused failure is specified
time since last status change—Time since the line
module was rebooted
Loopback State—Type of loopback configured at this
layer in the interface, or none
Last Remote Loopback Request Sent
BERT test—Number of current test and total number
of tests
Test interval—Length of the BERT test
status—Sync (controller is synchronized with remote
device) or NoSync (controller is not synchronized with remote device
Sync count—Number of times the pattern detector
synchronized with the incoming data pattern
Received bit count—Number of bits received
Error bit count—Number of bits with errors
Mode—Type of interface: SONET or SDH
Timing source—Type of clock source configured for
the channel:
internal module—Internal clock is from the line
module itself
chassis—Internal clock is from the configured router
clock
Current section alarms—Number of suspect bit patterns
found in several consecutive frames in section layer, or none
Current line alarms—Number of suspect bit patterns
found in several consecutive frames in line layer
Channel configuration—Parameters for specific controllers;
the actual parameters depend on the controller.
ifAdminStatus—State of the controller in the software
configuration: up or down
ifOperStatus—Physical state of the controller: up
or down
Time since last status change—Time the controller
has been up or down
Alarms—Number of suspect bit patterns found in several
consecutive frames
snmp trap link-status—State of SNMP link status
processing for the controller: enabled or disabled
alarms used for operational status calculation—Types
of defects that the router uses to determine the operational status
of the interface at the path layer
defect trigger soaking delay—Time that the router
waits to set an alarm when the router records a defect at the path
layer
c2 byte—Setting of path signal byte: set by upper
interface type (automatic setting) or configured value
Operational Status—Physical state of this layer:
up, down, or lowerLayerDown
time since last status change—Time since the line
module was rebooted
Framing—Type of framing configured for the controller:
Line Code—Type of line coding the router assigned
to the controller: B8ZS or AMI
Clock source—Type of clock source configured for
the channel:
module—Internal clock is from the line module itself
chassis—Internal clock is from the configured router
clock
J1 transmit trace message—Trace message sent to
the remote device
J1 expected trace message—Trace message expected
from the remote device
J1 received trace message—Trace message received
from the remote device
Example 1
host1#show controllers sonet 3/0 configuration
oc12 3/0
non channelized
ifAdminStatus: up
description: link1
snmp trap link-status: enabled
alarms used for operational status calculation: LOS LOF AIS RDI
defect trigger soaking delay: 2500 milliseconds
Operational Status: up
time since last status change: 00:03:30
Loopback State: none
Mode: sonet
Timing source: internal module
Receive FIFO Overruns: 0, Reconfigurations: 0
Current section defects: none
Current line defects: none
Channel configuration:
channel = 0, path = oc12, hierarchy = 1/1/0/0, current path defects: none
ifAdminStatus: up
snmp trap link-status: disabled
alarms used for operational status calculation: LOP AIS
defect trigger soaking delay: 2500 milliseconds
c2 byte override 20
Operational Status: up
time since last status change: 00:03:30
J1 transmit trace message: sonet3/0
J1 expected trace message: sonet4/0
J1 received trace message: sonet4/0
Example 2—If you do not specify the layer in the
interface, the router shows the configuration for all layers, whether
or not you specify the keyword configuration.
host1#show controllers sonet 2/1
oc3 2/1
channelized (3 channels, oc1 minimum speed)
ifAdminStatus: up
description: link1
snmp trap link-status: enabled
alarms used for operational status calculation: LOS LOF AIS RDI
defect trigger soaking delay: 2500 milliseconds
Operational Status: up
time since last status change: 00:03:30
Operational Status: up
time since last status change: 00:06:49
Loopback State: none
Mode: sonet
Timing source: internal module
Current section alarms: none
Current line alarms : none
Channel configuration:
channel = 1, path = oc1, hierarchy = 1/1/1/1, current path alarms: none
ifAdminStatus: up
snmp trap link-status: disabled
alarms used for operational status calculation: LOP AIS
defect trigger soaking delay: 2500 milliseconds
c2 byte override 20
Operational Status: up
time since last status change: 00:06:49
Ds3 1, unchannelized
ifOperStatus = ifOperUp
snmp trap link-status = disabled
Framing is C-BIT, Line Code is B3ZS, Clock Source is Internal - Module
Example 3—This example displays the configuration
for T3 1/1 on slot 2, port 1.
host1#show controllers sonet 2/1:1/1
oc3 2/1
channelized (3 channels, oc1 minimum speed)
ifAdminStatus: up
description: link1
snmp trap link-status: enabled
alarms used for operational status calculation: LOS LOF AIS RDI
defect trigger soaking delay: 2500 milliseconds
Operational Status: up
time since last status change: 00:03:30
Loopback State: none
Mode: sonet
Timing source: internal module
Current section alarms: none
Current line alarms : none
Channel configuration:
channel = 1, path = oc1, hierarchy = 1/1/1/1, current path alarms: none
ifAdminStatus: up
snmp trap link-status: disabled
alarms used for operational status calculation: LOP AIS
defect trigger soaking delay: 2500 milliseconds
c2 byte override 20
Operational Status: up
time since last status change: 00:05:37
Ds3 1, unchannelized
ifOperStatus = ifOperUp
snmp trap link-status = disabled
Framing is C-BIT, Line Code is B3ZS, Clock Source is Internal - Module
Use to display E1 or T1 (DS1) statistics for the different
layers in channelized SONET and SDH interfaces. Figure 8 shows the layers in the interface.
For definitions of the MIB statistics, see RFC 2495—Definitions
of Managed Objects for the DS1, E1, DS2 and E2 Interface Types (January
1999).
Specify an interface in slot/port format.
To view information for a specific controller in a layer,
enter the specifier for the controller and the type for the controller.
For example, to view the E1 controller 1/1/1 on path 1 on the interface
4/0, enter show controllers sonet 4/0:1/1/1/1 e1.
To view information for all controllers above a particular
layer, enter the specifier for the layer and the type for the controller.
For example, to view all E1 controllers on the interface 4/0 path
1, enter show controllers sonet 4/0:1 e1.
To view E1 or T1 statistics for a layer, specify the controller
type, e1 or ds1.
To view the configuration for a controller or all controllers
in a layer, omit the controller type.
Field descriptions
Description—Text description or alias if configured
for the interface
BERT test—Number of current test and total number
of tests
Test interval—Length of the BERT test
status—Sync (controller is synchronized with remote
device) or NoSync (controller is not synchronized with remote device
Sync count—Number of times the pattern detector
synchronized with the incoming data pattern
Received bit count—Number of bits received
Error bit count—Number of bits with errors
Number of valid intervals—Number of 15-minute intervals
since the line module was last powered on or reset
Time elapsed in current interval—Reported in 15-minute
intervals
Errored seconds—Number of errored seconds encountered
by a T1 or an E1 in the current interval
Severely errored seconds—Number of severely errored
seconds encountered by a T1 or an E1 in the current interval
Severely errored frame seconds—Number of severely
errored framing seconds encountered by a T1 or an E1 in the current
interval
Unavailable seconds—Number of unavailable seconds
encountered by a T1 or an E1 in the current interval
Clock slip seconds—Number of clock slips encountered
by a T1 or an E1 in the current interval
Path code violations—Number of coding violations
encountered by a T1 or an E1 in the current interval
Line errored seconds—Number of line errored seconds
encountered by a T1 or an E1 in the current interval
Bursty errored seconds—Number of bursty errored
seconds encountered by a T1 or an E1 in the current interval
Degraded minutes—Number of minutes that a T1 or
an E1 line is degraded
Line code violations—Number of line code violations
encountered by a T1 or an E1 in the current interval
Example—This example displays statistics for all
the E1 lines on the interface 2/0.
host1#show controllers sonet 2/0 e1
E1 1/1/1
Description: boston111 e1
BERT test - 2 in 11
Test Interval 1 minute(s), Running - Status is Sync
0 minute(s), 33 second(s) left in test interval
Sync count = 1
Received bit count = 41472000
Error bit count = 0
Number of valid interval - 0
Time elapse in current interval - 0
Use to display T3 statistics for the different layers
in channelized SONET and SDH interfaces. Figure 8 shows the layers in the interface.
For definitions of the MIB statistics, see RFC 2496—Definitions
of Managed Objects for the DS3/E3 Interface Types (January 1999).
Specify an interface in slot/port format.
To view information for a specific controller in a layer,
enter the specifier for the controller and the type for the controller.
For example, to view T3 controller 1 on path 1 on the interface 4/0,
enter show controllers sonet 4/0:1/1 ds3.
To view information for all controllers above a particular
layer, enter the specifier for the layer and the type for the controller.
For example, to view all DS3 controllers on the interface 4/0, enter show controllers sonet 4/0 ds3.
To view T3 statistics for a layer, specify the controller
type, ds3.
To view the configuration for a controller or all controllers
in a layer, omit the controller type.
Field descriptions
Description—Text description or alias if configured
for the interface
BERT test—Number of current test and total number
of tests
Test interval—Length of the BERT test
status—Sync (controller is synchronized with remote
device) or NoSync (controller is not synchronized with remote device
Sync count—Number of times the pattern detector
synchronized with the incoming data pattern
Received bit count—Number of bits received
Error bit count—Number of bits with errors
Number of valid intervals—Number of 15-minute intervals
since the line module was last powered on or reset
Time elapse in current interval—Time (seconds) passed
in current interval
Current Interval Counters—Statistics for the current
15-minute interval
P-bit errored seconds—Number of errored seconds
encountered by a T3
P-bit severely errored seconds—Number of severely
errored seconds encountered by a T3
Severely errored frame seconds—Number of severely
errored framing seconds encountered by a T3
Unavailable seconds—Number of unavailable seconds
encountered by a T3
Line code violations—Number of line code violations
encountered by a T3
P-bit coding violations—Number of coding violations
encountered by a T3
Line errored seconds—Number of line errored seconds
encountered by a T3
C-bit coding violations—Number of C-bit coding violations
encountered by a T3
C-bit errored seconds—Number of C-bit errored seconds
encountered by a T3
C-bit severely errored seconds—Number of C-bit severely
errored seconds encountered by a T3
24 Hour Total counters—Statistics for last 24 hours
Example 1—This example shows all T3 controllers
on the interface 2/1.
host1#show controllers sonet 2/1 ds3
Ds3 1
Description: ottawa211 ds3
Number of valid interval - 0
Time elapse in current interval - 696
show controllers sonet line | path | section | tributary
Use to display statistics for the different layers in
channelized SONET and SDH interfaces. Figure 8 shows the layers in the interface.
For definitions of the MIB statistics, see RFC 2558—Definitions
of Managed Objects for the SONET/SDH Interface Type (March 1999).
Specify an interface in slot/port format.
To view information for a specific controller in a layer,
enter the specifier for the controller and the type for the controller.
For example, to view tributary 1/1/1 on path 1 of interface 4/0, enter show controllers sonet 4/0:1/1/1/1 tributary.
To view information for all controllers above a particular
layer, enter the specifier for the layer and the type for the controller.
For example, to view all tributaries on path 1 of interface 4/0, enter show controllers sonet 4/0:1 tributary.
To view statistics for a layer, specify the type of layer.
To view the configuration for a controller or all controllers
in a layer, omit the controller type.
To view all statistics for all sessions, specify the total keyword.
To view baselined statistics for all intervals, specify
the delta total keywords.
Field descriptions
Current Interval Counters—Statistics for the current
15-minute interval
Errored seconds—Number of errored seconds encountered
by a T1 or an E1 in an interval
Severly errored seconds—Number of severely errored
seconds encountered in an interval
Severly errored framing seconds—Number of severely
errored framing seconds encountered in an interval
Coding violations—Number of coding violations encountered
in an interval
Unavailable seconds—Number of unavailable seconds
encountered in an interval
Last Interval Counters—Statistics for the previous
15-minute interval
Current Far End Interval Counters—Statistics for
the remote connection associated with the SONET/SDH path in the current
15-minute interval
Last Far End Interval Counters—Statistics for the
remote connection associated with the SONET/SDH path in the previous
15-minute interval
Total interval counters—Shows the statistics for
all intervals or baselined statistics
Example 1—This example shows the MIB statistics
for the section layer on interface 2/1.
host1#show controllers sonet 2/1 section
Current Section Interval Counters
Current status = No Defect
Errored seconds = 0
Severly errored seconds = 0
Severely errored framing seconds = 0
Coding violations = 0
Example 2—This example illustrates the behavior
of the baseline section interface
sonet command. The examples show the MIB statistics
of the section layer before and after the command is issued.
host1#show controllers sonet 2/0 section total
Number of valid intervals - 0
Time elapsed in current interval - 192
Current Section Interval Counters
Current status = No Defect
Errored seconds = 68
Severly errored seconds = 68
Severely errored framing seconds = 2
Coding violations = 4018
host1#show controllers sonet 2/0 section total delta
Number of valid intervals - 0
Time elapsed in current interval - 209
Current Section Interval Counters
Current status = No Defect
Errored seconds = 68
Severly errored seconds = 68
Severely errored framing seconds = 2
Coding violations = 4018
Use to display MIB statistics for the remote end of a
channelized T3 interface configured for MDL or for the remote end
of a T1 channel configured for FDL.
Specify the all option to display detailed information
for all 15-minute intervals.
For definitions of the MIB statistics for a T3 connections,
see RFC 2496—Definitions of Managed Objects for the DS3/E3 Interface
Types (January 1999).
For definitions of the MIB statistics for a T1 connections,
see RFC 2495—Definitions of Managed Objects for the DS1, E1,
DS2 and E2 Interface Types (January 1999).
Field descriptions for a T3 interface
Far End MDL Carrier bit—Status of MDL configuration
on remote device connected to T3 interface
set—MDL is configured for carrier mode
not set—MDL is not configured for carrier mode
Far End Equipment Identification Code—eic string
sent by remote device for MDL
Far End Line Identification Code—lic string sent
by remote device for MDL
Far End Frame Identification Code—fic string sent
by remote device for MDL
Far End Unit Identification Code—unit string sent
by remote device for MDL
Far End Facility Identification Code—pfi string
sent by remote device for MDL
Far End Generator Number—generator string sent by
remote device for MDL
Far End Port Number—port string sent by remote device
for MDL
Number of valid intervals—Number of 15-minute intervals
since the line module was last powered on or reset
Time elapse in current interval—Number of seconds
that have passed in the 15-minute (900-second) interval
C-bit errored seconds—Number of C-bit errored seconds
encountered by a T3 in the current interval
C-bit severely errored seconds—Number of C-bit severely
errored seconds encountered by a T3 in the current interval
C-bit coding violations—Number of C-bit coding violations
encountered by a T3 in the current interval
Unavailable seconds—Number of unavailable seconds
encountered by a T3 in the current interval
Invalid seconds—Number of seconds when statistics
were not collected
Field descriptions for a T1 channel
DS1—Identifier of T1 channel
Number of valid intervals—Number of 15-minute intervals
since the line module was last powered on or reset
Time elapse in current interval—Number of seconds
that have passed in the 15-minute (900-second) interval
Far End FDL Carrier bit—Status of FDL configuration
on remote device connected to T1 channel
set—FDL is configured for carrier mode
not set—FDL is not configured for carrier mode
Far End Equipment Identification Code—eic string
sent by remote device for FDL
Far End Line Identification Code—lic string sent
by remote device for FDL
Far End Frame Identification Code—fic string sent
by remote device for FDL
Far End Unit Identification Code—unit string sent
by remote device for FDL
Far End Facility Identification Code—pfi string
sent by remote device for FDL
Far End Generator Number—generator string sent by
remote device for FDL
Far End Port Number—port string sent by remote device
for FDL
Errored seconds—Number of errored seconds encountered
by a T1 in the current interval
Severely errored seconds—Number of severely errored
seconds encountered by a T1 in the current interval
Severely errored frame seconds—Number of severely
errored framing seconds encountered by a T1 in the current interval
Unavailable seconds—Number of unavailable seconds
encountered by a T1 in the current interval
Clock slip seconds—Number of clock slips encountered
by a T1 in the current interval
Path code violations—Number of coding violations
encountered by a T1 in the current interval
number of coding violations encountered by a T1 in the
current interval
Line errored seconds—Number of line errored seconds
encountered by a T1 in the current interval
Bursty errored seconds—Number of bursty errored
seconds encountered by a T1 in the current interval
Degraded minutes—Number of minutes that a T1 line
is degraded
Example 1—In this example, a T3 interface is specified.
host1#show controllers sonet 5/0:1/1 remote
Far End MDL Carrier bit is not set
Far End Equipment Identification Code is the null string
Far End Line Identification Code is the null string
Far End Frame Identification Code is the null string
Far End Unit Identification Code is the null string
Far End Facility Identification Code is the null string
Far End Generator Number is the null string
Far End Port Number is the null string
Number of valid interval - 3
Time elapse in current interval - 756
Example 2—In this example, a T1 channel on a T3
over channelized SONET interface is specified.
host1#show controllers sonet 5/0:1/1/1 remote
DS1 10/1:1
Number of valid interval - 0
Time elapse in current interval - 0
Far End FDL Carrier bit is not set
Far End Equipment Identification Code is the null string
Far End Line Identification Code is the null string
Far End Frame Identification Code is the null string
Far End Unit Identification Code is the null string
Far End Facility Identification Code is the null string
Far End Port Number is the null string
Far End Generator Number is the null string
Example 3—In this example, a T1 over channelized
SONET interface is specified.
host1#show controllers sonet 5/0:1/1/1/2/2 remote
DS1 10/1:1
Number of valid interval - 0
Time elapse in current interval - 0
Far End FDL Carrier bit is not set
Far End Equipment Identification Code is the null string
Far End Line Identification Code is the null string
Far End Frame Identification Code is the null string
Far End Unit Identification Code is the null string
Far End Facility Identification Code is the null string
Far End Port Number is the null string
Far End Generator Number is the null string