Configures the transmit clock source for DS1 or
E1 channels over channelized SONET and SDH interfaces. The no version restores the default value.
Options
pathChannel—Number, in the
range 1–2147483648, that identifies the path
tributaryIdentifier—Specifier
for the tributary in the format pathChannel { ds1 | e1 } pathPayload/tributaryGroup/tributaryNumber
pathPayload—Payload number
for the path; value is 1 for SONET and in the range 1–3 for
SDH
tributaryGroup—Number, in
the range 1–7, that identifies the group within the path
tributaryNumber—Number of
the tributary within the tributary group; the value is in the range
1–4 if the tributary type is vt15 or tu11 and in the range 1–3
if the tributary type is tu12
line—Interface transmits data from a clock recovered
from the line’s receive data stream.
internal—Interface transmits data using its internal
clock. You must specify one of the following for internal clocking:
module—Internal clock is from the line module itself
chassis—Internal clock is from the configured system
clock