interfaceSpecifier—Particular
interface; format varies according to interface type; see Interface Types and Specifiers. The autoRP announcement messages will contain
the IP address for this interface.
accessListName—Access-list
containing the set of group prefixes supported by this C-RP. If no
group-list is specified, the default value is the entire multicast
address range.
holdTime—Amount of time in
the range 1–65535 seconds that the BSR keeps an RP in its C-RP
list if the BSR does not receive a C-RP advertisement message; default
value is 150 seconds
priority—Priority field value
in the range 0– 255 that the C-RP sends to the BSR in C-RP advertisement
messages; default value is 192. In the RP election process, the RP
with the lower priority value is preferred.
interval—Interval in the range
1–65535 seconds at which the C-RP sends advertisement messages
to the BSR; default value is 60 seconds