Use to specify a previously configured packet over SONET
(POS) interface on which you want to configure PPP.
To specify a POS interface for ERX-7xx models, ERX-14xx
models, and ERX-310 routers, use the slot/port.[subinterface ] format.
slot—Number of the chassis
slot
port—Port number on the I/O
module
subinterface—Number of the
subinterface
To specify a POS interface for E120 and E320 routers,
use the slot/adapter/port format.
slot—Number of the chassis
slot
adapter—Identifier for the
IOA within the E320 chassis, either 0 or 1, where:
0 indicates that the IOA is installed in the right IOA
bay (E120 router) or the upper IOA bay (E320 router).
1 indicates that the IOA is installed in the left IOA
bay (E120 router) or the lower IOA bay (E320 router).
port—Port number on the IOA
For more information about modules that support POS interfaces,
see chapter Configuring Unchannelized OCx/STMx Interfaces in JUNOSe Physical Layer Configuration Guide.
Use to specify a serial interface in the slot/port:channel/subchannel
format by selecting a previously configured physical interface on
which you want to configure PPP.
slot—Refers to a router chassis
slot.
port—Refers to a CT3, T3,
or E3 module I/O port.
channel—Refers to a T1 (DS1)
channel.
subchannel—Represents a set
of DS0 subchannels.
Example
host1(config)#interface serial 3/0:2/5
Use the no version to disable