Configures RIP timers. The no version restores the default values.
Options
update—Interval in seconds
at which routing updates are sent; default value is 30
invalid—Interval in seconds
after which a route is declared invalid (null); default value is 180
holddown—Interval in seconds
during which routing information regarding better paths is disregarded
by the router; default value is 120
flush—Interval in seconds
that must pass before a route is removed from the routing table; set
this value greater than the invalid value; default value is 300
Mode
Address Family Configuration, Router Configuration