no path pathChannel ds3 ds3Channel t1 t1Channel clock source
Release Information
Command introduced before JUNOSe Release
7.1.0.
Description
Configures the transmit clock source for a T1 channel
on a DS3 signal. This command applies to a T1 channel on a DS3 over
channelized SONET interface. The no version
restores the default value, line.
Options
pathChannel—Number, in the
range 1–2147483648, that identifies the path
ds3Channel—Number, in the
range 1–3, that identifies the DS3 channel
t1Channel—One or more individual
T1 channels, ranges of T1 channels, or combination of individual channels
and ranges, in the range 1–28 (no spaces); for example, 3,7-15,19-13,27
line—Interface transmits data from a clock recovered
from the line’s receive data stream
internal—Interface transmits data using its internal
clock. You must specify one of the following for internal clocking:
module—Internal clock is from the line module itself
chassis—Internal clock is from the configured system
clock