no path pathChannel ds3 ds3Channel mdl string { eic | fic | generator | lic | pfi | port | unit }
Release Information
Command introduced before JUNOSe Release
7.1.0.
Description
Allows you to configure an MDL message on a DS3
signal as defined in the ANSI T1.107a-1990 specification. This command
applies to a DS3 over channelized SONET interface. The no version restores the default value to the specified
MDL message or to all MDL messages.
Options
pathChannel—Number, in the
range 1–2147483648, that identifies the path
ds3Channel—Number, in the
range 1–3, that identifies the path
eicValue—Equipment identification
code; 1–10 characters; default value is the null value
ficValue—Frame identification
code; 1–10 characters; default value is the null value
genValue—Generator number
to send in the MDL test signal message; 1–38 characters; default
value is the null value
licValue—Line identification
code; 1–11 characters; default value is the null value
pfiCode—Facility identification
code to send in the MDL path message; 1–38 characters; default
value is the null value
portValue—Equipment port number
to send in the MDL idle signal message; 1–38 characters; default
value is the null value
unitValue—Unit identification
code; 1–6 characters; default value is the null value