Monitoring Chassis Information
Purpose
Use the monitoring functionality to view chassis properties
such as general switch information, temperature and fan status, and
resource information for the EX Series switch.
Action
To view chassis properties in the J-Web interface, select Monitor > System View > Chassis Information.
To view chassis properties in the CLI, enter the following commands:
- show chassis environment
- show chassis fpc
- show chassis hardware
Meaning
Table 1 gives information about the key output fields for chassis
information.
 |
Note:
For an EX3200 switch or an EX4200 standalone
switch, FPC refers to the switch itself. In a Virtual Chassis configuration,
FPC refers to the member switch. In an EX8200 switch, FPC refers to
the line card.
|
Table 1: Summary of the Key Output Fields for Chassis Information
Field
|
Values
|
Routing Engine Details
|
Select the Master tab to view details
about the master Routing Engine or select Backup to view
details about the backup Routing Engine.
|
Name/Value
|
This table displays the following details
of the master Routing Engine:
- Slot
- Model
- Version
- Part number
- Serial number
- Memory utilization
- Temperature
- Start time
- CPU load average for 1, 5, and 15 minutes
|
Power
and Fan Tray Details
|
Power
|
Select the Power tab to view details
of the power supplies.
|
Name/Value
|
Displays the status and model number of each
power supply.
|
Fan
|
Select the Fan tab to view details
about the fans.
|
Name/Value
|
Displays the status of each fan in the corresponding
FPC.
|
Chassis
Component Details
|
Select component
|
Select an FPC to view General, Temperature, and Resource details.
|
General
|
Select the General tab to view the
general information about the chassis components.
|
Name/Value
|
Displays general information:
- Version—Revision level. Supply the version number
when reporting hardware problems to customer support.
- Part Number
- Serial Number—Supply the serial number when contacting
customer support about the switch chassis.
- Description—Brief text description.
|
Temperature
|
Select the Temperature tab to view
the temperature details of the components in the selected FPC.
|
Name/Value
|
Displays the temperature details of the sensors
present in the selected FPC.
|
Resource
|
Select the Resource tab to view the
resource details of the selected FPC.
|
Name/Value
|
Displays resource details:
- State:
- Dead—Held in reset because of errors.
- Diag—The FPC is running diagnostics.
- Dormant—Held in reset.
- Empty—No FPC is present.
- Online—The FPC is online and running.
- Probed—Probe is complete. The FPC is awaiting
restart of the Packet Forwarding Engine (PFE).
- Probe-wait—The FPC is waiting for the probe
operation to start.
- Total CPU DRAM—Total DRAM, in megabytes,
available to the FPC.
- Start time—Date and time the switch was
last rebooted.
|
Published: 2009-08-31