The phase lock loop (PLL) alarm occurs when the PLL cannot lock on to a timing device, and indicates a possible hardware or network timing problem.
To display SONET alarms and errors, use the following JUNOS CLI operational mode command:
Sample Output
user@host> show interfaces so-1/1/1 extensive [...Output truncated...]
Active alarms : PLL
Active defects : PLL
SONET PHY: Seconds Count State
PLL Lock 26 0 PLL Lock Error
PHY Light 0 0 OK
SONET section:
BIP-B1 0 0
SEF 0 0 OK
LOS 0 0 OK
LOF 0 0 OK
ES-S 0
SES-S 0
SEFS-S 0
SONET line:
BIP-B2 0 0
REI-L 0 0
RDI-L 3 3 OK
AIS-L 0 0 OK
BERR-SF 0 0 OK
BERR-SD 0 0 OK
ES-L 0
SES-L 0
UAS-L 0
ES-LFE 0
SES-LFE 0
UAS-LFE 0
SONET path:
BIP-B3 0 0
REI-P 0 0
LOP-P 0 0 OK
AIS-P 0 0 OK
RDI-P 0 0 OK
UNEQ-P 0 0 OK
PLM-P 0 0 OK
ES-P 0
SES-P 0
UAS-P 0
ES-PFE 0
SES-PFE 0
UAS-PFE 0
[...Output truncated...]
Meaning
The sample output shows a PLL alarm lasting for 26 seconds. You must investigate the timing source to diagnose the problem. The timing source is derived from an incoming SONET circuit (when clock external is configured), or from the onboard Stratum 3 clock (when clock internal is configured). Internal clocking is the default for Juniper Networks routers.
The cause of the problem differs depending on the type of system board on the router. (See Table 36.) For example:
To further diagnose the problem, try the following:
Table 36 shows the location of the onboard clock on the various system boards of Juniper Networks routers.
Table 36: Location of the Onboard Clock