To verify the status of the logical interface, use the following JUNOS CLI operational mode command:
![]() |
Note: For a list of interface types associated with the Channelized OC12 IQ interface, see . |
Sample Output
user@host> show interfaces t3-0/3/0:11 Physical interface: t3-0/3/0:11, Enabled, Physical link is Up
Interface index: 204, SNMP ifIndex: 129
Link-level type: Cisco-HDLC, MTU: 4474, SONET mode, Speed: T3, Loopback: Local,
SONET Loopback: None, FCS: 16, Mode: C/Bit parity
Device flags : Present Running
Interface flags: Point-To-Point SNMP-Traps
Link flags : No-Keepalives
CoS queues : 4 supported
Last flapped : 2004-05-21 15:23:34 UTC (01:34:24 ago)
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
DS3 alarms : None
SONET alarms : None
DS3 defects : None
SONET defects : None
DS-3 BERT configuration:
BERT time period: 0 seconds, Elapsed: 0 seconds
Algorithm: Unknown (0), Induced error rate: 10e-0
Logical interface t3-0/3/0:11.0 (Index 71) (SNMP ifIndex 130)
Flags: Point-To-Point SNMP-Traps Encapsulation: Cisco-HDLC
Protocol inet, MTU: 4470
Flags: None
Addresses, Flags: Is-Preferred Is-Primary
Destination: 10.0.0.0/30, Local: 10.0.0.1, Broadcast: 10.0.0.3
Meaning
The sample output shows that the channelized interface has the physical and logical links up. There are no alarms or defects. If there are SONET layer errors, see Investigate SONET Interfaces, for information on diagnosing SONET interface problems.