pdu-interval
Syntax
Hierarchy Level
- [edit protocols oam ethernet link-fault-management interface interface-name]
Release Information
Statement introduced in JUNOS Release 9.4 for EX-series switches.
Description
Specify the periodic OAM PDU sending interval for fault detection. It is used for IEEE 802.3ah Operation, Administration, and Maintenance (OAM) link fault management (LFM) support.
Options
-
interval—Periodic OAM PDU sending interval.
- Range: 400 through 1000 milliseconds
- Default: 1000 milliseconds
Required Privilege Level
interface—To view this statement in the
configuration.
interface-control—To add this
statement to the configuration.