Checking Active Alarms on the Switch with the J-Web Interface
The alarm information includes alarm type,
alarm severity, and a brief description for each active alarm on the
switch. To view the active alarms, click Alarms in the taskbar of the J-Web interface or enter the following CLI show commands:
-
show chassis alarms
-
show system alarms
 |
Note:
If a switch has active alarms and you have not displayed the View
Alarms page, Alarms appears in red in the taskbar
. After you display the page, Alarms returns
to white. If new alarms become active, Alarms is red until you again display the View Alarms page.
|
shows the View
Alarms summary page. Click an alarm in the list of active alarms to
display a detailed alarm message.
Table 1 summarizes the output
fields on the alarms page.
Table 1: Summary of Key Alarm Output Fields
|
Field
|
Values
|
Additional Information
|
| Alarm Summary |
|
New?
|
Viewed status of the alarm—either Yes
(a new alarm) or No (a previously viewed alarm).
|
After you have displayed the View Alarms page,
any new alarms that appear on the page during the same J-Web session
are identified as previously viewed.
|
|
Received at
|
Date and time when the alarm condition was
detected.
| |
|
Severity
|
Alarm severity—either major (red) or
minor (yellow).
|
A major (red) alarm severity level requires
immediate action. A minor (yellow) severity level requires monitoring
or maintenance.
|
|
Subject
|
Brief synopsis of the alarm.
|
Clicking the alarm subject displays a detailed
alarm message.
|
| Detailed Alarm Message |
|
Received at
|
Date and time when the failure was detected.
| |
|
Severity
|
Alarm severity—either
major (red) or minor (yellow).
|
A major
(red) alarm severity level requires immediate action. A minor (yellow)
severity level requires monitoring or maintenance.
|
|
Alarm Type
|
Category of the alarm:
- Chassis—Indicates an alarm condition on the chassis
(typically an environmental alarm such as temperature).
- Configuration—Indicates that no rescue configuration
is set.
- ETHER—Indicates an alarm condition on an Ethernet
interface.
- DS3—Indicates an alarm condition on a DS3 interface.
- License—Indicates a software license infringement.
- Serial—Indicates an alarm condition on a serial
interface.
- Services—Indicates an alarm condition on the services
module.
| |