Technical Documentation

frame-error

Syntax

frame-error count;

Hierarchy Level

[edit protocols oam ethernet link-fault-management event link-event-rate],
[edit protocols oam ethernet link-fault-management interface interface-name event-thresholds ]

Release Information

Statement introduced in JUNOS Release 9.4 for EX-series switches.

Description

Configure the threshold value for sending frame error events or taking the action specified in the action profile.

Frame errors occur on the underlying physical layer. The threshold is reached when the number of frame errors reaches the configured value.

Options

count—Threshold count in seconds for frame error events.

Range: 1 through 100 seconds
Default: 1 second

Required Privilege Level

interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.