show chassis alarms
Syntax
- show chassis alarms
Syntax (Routing Matrix)
- show chassis alarms
- <lcc number | scc>
Release Information
Command introduced before JUNOS Release 7.4.
Description
Display information about the conditions that have been configured to trigger alarms.
Options
none — (Routing matrix only) Display information about the conditions that have been configured to trigger alarms on the TX Matrix platform and its attached T640 routing nodes.
lcc number — (Routing matrix only) (Optional) Show information about a specified T640 routing node (or line-card chassis) that is connected to a TX Matrix platform. Replace number with a value from 0 through 3.
scc — (Routing matrix only) (Optional) Show information about the TX Matrix platform (or switch-card chassis).
Additional Information
You cannot clear the alarms for chassis components. Instead, you must remedy the cause of the alarm. When a chassis alarm is lit, it indicates that you are running the router in a manner that we do not recommend.
You can manually silence external devices connected to the alarm relay contacts by pressing the alarm cutoff button, located on the craft interface. Silencing the device does not remove the alarm messages from the display (if present on the router) or extinguish the alarm LEDs. In addition, new alarms that occur after you silence an external device reactivate the external device.
Required Privilege Level
view
List of Sample Output
show chassis alarms (Alarms Active)show chassis alarms (No Alarms Active)
show chassis alarms (Alarms Active on a Routing Matrix)
show chassis alarms (Backup Routing Engine)
Output Fields
Table 1 lists the output fields for the show chassis alarms command. Output fields are listed in the approximate order in which they appear.
Table 1: show chassis alarms Output Fields
|
Field Name |
Field Description |
|---|---|
|
Alarm time |
Date and time the alarm was first recorded. |
|
Class |
Severity class for this alarm: Minor or Major. |
|
Description |
Information about the alarm. |
Sample Output
show chassis alarms (Alarms Active)
user@host> show chassis alarms
3 alarms are currently active Alarm time Class Description 2000-02-07 10:12:22 UTC Major fxp0: ethernet link down 2000-02-07 10:11:54 UTC Minor YELLOW ALARM - PEM 1 Removed 2000-02-07 10:11:03 UTC Minor YELLOW ALARM - Lower Fan Tray Removed
show chassis alarms (No Alarms Active)
user@host> show chassis alarms
No alarms are currently active
show chassis alarms (Alarms Active on a Routing Matrix)
user@host> show chassis alarms
scc-re0: -------------------------------------------------------------------------- 8 alarms currently active Alarm time Class Description 2004-08-05 18:43:53 PDT Minor LCC 0 Minor Errors 2004-08-05 18:43:53 PDT Minor SIB 3 Not Online 2004-08-05 18:43:52 PDT Major SIB 2 Absent 2004-08-05 18:43:52 PDT Major SIB 1 Absent 2004-08-05 18:43:52 PDT Major SIB 0 Absent 2004-08-05 18:43:33 PDT Major LCC 2 Major Errors 2004-08-05 18:43:28 PDT Major LCC 0 Major Errors 2004-08-05 18:43:05 PDT Minor LCC 2 Minor Errors lcc0-re0: -------------------------------------------------------------------------- 5 alarms currently active Alarm time Class Description 2004-08-05 18:43:53 PDT Minor SIB 3 Not Online 2004-08-05 18:43:49 PDT Major SIB 2 Absent 2004-08-05 18:43:49 PDT Major SIB 1 Absent 2004-08-05 18:43:49 PDT Major SIB 0 Absent 2004-08-05 18:43:28 PDT Major PEM 0 Not OK lcc2-re0: -------------------------------------------------------------------------- 5 alarms currently active Alarm time Class Description 2004-08-05 18:43:35 PDT Minor SIB 3 Not Online 2004-08-05 18:43:33 PDT Major SIB 2 Absent 2004-08-05 18:43:33 PDT Major SIB 1 Absent 2004-08-05 18:43:33 PDT Major SIB 0 Absent 2004-08-05 18:43:05 PDT Minor PEM 1 Absent
show chassis alarms (Backup Routing Engine)
user@host> show chassis alarms
2 alarms are currently active Alarm time Class Description 2005-04-07 10:12:22 PDT Minor Host 1 Boot from alternate media 2005-04-07 10:11:54 PDT Major Host 1 compact-flash missing in Boot List