Juniper Networks
Log in
|
How to Buy
|
Contact Us
|
United States (Change)
Choose Country
Close

Choose Country

North America

  • United States

Europe

  • Deutschland - Germany
  • España - Spain
  • France
  • Italia - Italy
  • Россия - Russia
  • United Kingdom

Asia Pacific

  • Asean Region (Vietnam, Indonesia, Singapore, Malaysia)
  • Australia
  • 中国 - China
  • India
  • 日本 - Japan
  • 대한민국 - Korea
  • 台灣 - Taiwan
Solutions
Products & Services
Company
Partners
Support
Education
Community
Security Intelligence Center

Technical Documentation

Technical Documentation
 
CLI Explorer New
 
Content Explorer New
 
Documentation Help New
 
Enterprise MIBs
 
EOL Documentation
 
Feature Explorer Login required New
 
Glossary
 
Portable Libraries
 
Home > Support > Technical Documentation > Configuring Aggregated Ethernet Minimum Links
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • M Series
  • aggregated-ether-options
  • minimum-links
  • MX Series
  • aggregated-ether-options
  • minimum-links
  • T Series
  • aggregated-ether-options
  • minimum-links
  • Additional Information
  • Junos OS Ethernet Interfaces Configuration Guide PDF Document
 

Configuring Aggregated Ethernet Minimum Links

On aggregated Ethernet interfaces, you can configure the minimum number of links that must be up for the bundle as a whole to be labeled up. By default, only one link must be up for the bundle to be labeled up.

To configure the minimum number of links:

  1. Specify that you want to configure the aggregated Ethernet options.
    user@host# edit interfaces interface-name aggregated-ether-options
  2. Configure the minimum number of links.
    [edit interfaces interface-name aggregated-ether-options]user@host# set minimum-links number

On M120, M320, MX Series, T Series, and TX Matrix routers with Ethernet interfaces, the valid range for minimum-links number is 1 through 16. When the maximum value (16) is specified, all configured links of a bundle must be up for the bundle to be labeled up.

On all other routers and on EX Series switches, other than EX8200 switches, the range of valid values for minimum-links number is 1 through 8. When the maximum value (8) is specified, all configured links of a bundle must be up for the bundle to be labeled up.

On EX8200 switches, the range of valid values for minimum-links number is 1 through 12. When the maximum value (12) is specified, all configured links of a bundle must be up for the bundle to be labeled up.

If the number of links configured in an aggregated Ethernet interface is less than the minimum link value configured under the aggregated-ether-options statement, the configuration commit fails and an error message is displayed.

 

Related Documentation

  • M Series
  • aggregated-ether-options
  • minimum-links
  • MX Series
  • aggregated-ether-options
  • minimum-links
  • T Series
  • aggregated-ether-options
  • minimum-links
  • Additional Information
  • Junos OS Ethernet Interfaces Configuration Guide PDF Document
 

Published: 2011-11-03

 
  • About Juniper
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Green Networking
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Developers
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2013 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out